Advanced Entry Calibration (continued)
Step
Action
Displayed Message
Comment
J
Use the buttons to increment the
Gain Number by one. Record the
TOF Value. Repeat this process for
each Gain Number.
TRAN SENSOR GAIN
yyy
(0 - 31)
01
These are TOF Values, where
“yyy” represents the current
sensor reading.
Sample Calibration Table
Gain Number
Label Value
TOF Value
Difference Value
00
252
248
01
250
245
02
248
234
…
…
…
31
09
14
Step
Action
Displayed Message
Comment
K
In your sample calibration table,
where both the Label Value and
TOF Value are at least 20, subtract
the amounts and record the result
as a Difference Value (see below).
Identify the largest Difference
Value and the corresponding Gain
Number. This Gain Number will be
used to resample the media.
TRAN SENSOR GAIN
yyy
(0 - 31)
31
In this example, Gain Number 18
is chosen because, where both
values are at least twenty, it has
the highest Difference Value.
Sample Calibration Table
Gain Number
Label Value
TOF Value
Difference Value
00
252
248
4
01
250
245
5
02
248
234
14
…
…
…
…
15
188
63
125
16
184
51
133
17
179
38
141
18
174
25
149
19
170
19
N/A
…
…
…
…
31
132
14
N/A