I-Class
Appendix D
Configuration Files
With application version 5.01 and above, the printer can save and restore complete printer
settings, including media calibration parameters, in internal Configuration Files. Here are the
highlights and restrictions of the feature:
•
Eliminates the need to repeat the manual steps of a special printer setup, making
future changeovers faster and easier.
•
Can be setup, saved, and restored either from the host or via the menu as “C-type”
files on Module Y under unique filenames of up to nineteen characters in length.
•
Enables the host, via special DPL commands, to control parameters previously
accessible only from the Control Panel.
Note: If file sharing among printers, do not include unique parameters (such as
calibrations and adjustments).
When using the Control Panel to save a configuration file (see Section 4.2.5), the keypad
functions are as follows:
The DOWN ARROW Key scrolls down through the
alphanumeric, underscore, and delete character
.
The UP ARROW Key scrolls up through the alphanumeric and
underscore characters, and the delete function.
The ENTER Key accepts the displayed character and
advances the cursor.
The ESCAPE Key saves the displayed file.