11.
Remove the 6 retaining screws (T30) connecting each IGBT module output to the IGBT
output bus bars.
12.
Remove the retaining nut (17 mm) connecting the IGBT output bus bar to IGBT overfan
bus bar. Note that there is one for each of three phases.
13.
Remove the retaining nut (17 mm) or T50 Torx screw, depending on the unit type, con-
necting to IGBT overfan bus bar to current sensor bus bar.
14.
Remove the 3 retaining nuts (17 mm) at top and one retaining nut (8 mm) at bottom
attaching IGBT output bus bar to standoffs. Remove the IGBT output bus bar.
CONTINUED NEXT PAGE
130BX104.10
1
2
3
4
5
1
6
7
Figure 8.16: IGBT Modules (3 of 4)
1
Retaining screw (Step 11)
5
Retaining nut (Step 12)
2
Retaining nut (Step 14)
6
Overfan bus bar
3
Output bus bar
7
Retaining nut (Step 13)
4
Retaining nut (Step 14)
8 E-Frame Sizes Disassembly and Assembly