7.
Remove twelve (T30) screws from the output (lower) side of the IGBT modules.
8.
Remove the retaining nut (8 mm) from each intermediate IGBT output bus bar. Remove
the intermediate IGBT bus bars.
9.
Remove 4 nuts (10 mm), two on either side, connecting the rectifier DC bus bars to the
main DC bus bars. These are located to either side of the SCR/diode modules.
CONTINUED NEXT PAGE
130BX84.10
1
2
3
4
5
6
7
8
9
10
11
Figure 7.13: D2/D4 SCR/Diode Module (2 of 4)
1
Retaining screws (Step 9)
7
IGBT output retaining screws (Step 7)
2
Retaining nut (Step 8)
8
Retaining screws (Step 9)
3
IGBT module
9
Intermediate IGBT output bus bar BB30 (Step 8)
4
Main DC bus bar BB25 (Step 9)
10
Bus bar BB31
5
Bus bar BB27
11
Bus bar BB30
6
Bus bar BB26
High Power Service Manual for VLT
®
FC Series
Adjustable Frequency Drives
7 D-Frame Sizes Disassembly and Assembly
Instructions
MG.90.L1.22 - VLT
®
is a registered Danfoss trademark
7-15
7
Содержание VLT HVAC FC 100
Страница 219: ......
Страница 220: ...Rev 2008 09 01 www danfoss com drives 130R0438 MG90L122 MG90L122 High Power Service Manual MG90L122...