7.2.11 SCR/Diode Module D2/D4 Units
1.
Remove the lower DC capacitor bank per instructions.
2.
Remove the input terminal plate per instructions.
3.
Remove the retaining nuts (8 mm) from the SCR input bus bars, one for each input phase.
4.
Note the color coding for each of the three wires attached to the retaining studs. Ensure
that the correct wire is attached to the applicable stud during reassembly. Remove the
wiring from the studs.
5.
Remove screw (T30) from terminal 1 of each SCR/diode module by accessing the screw
through access hole in the SCR/diode input bus bar. Remove the SCR input bus bars.
6.
Remove each IGBT output bus bar by removing the nut (13 mm) from the stud. Also
remove the retaining screw (T40) at other end of the IGBT output bus bars (not shown).
CONTINUED NEXT PAGE
130BX161.10
1
2
3
4
5
6
Figure 7.12: D2/D4 SCR/Diode Module (1 of 4)
1
SRC/diode input bus bar retaining nut and stud (Steps 3 & 4) 4
IGBT output bus bar retaining nut (Step 6)
2
SRC/diode terminal screw (Step 5)
5
SRC/diode terminal screw (Step 5)
3
SRC/diode input bus bar BB21 or BB22 per drive power rating 6
IGBT output bus bar BB32 (Step 6)
7 D-Frame Sizes Disassembly and Assembly