0-13 Readout: Linked Set-ups
Array [5]
Range:
Function:
0
*
[0 - 255 ] View a list of all the set-ups linked by means of
0-12 This Set-up Linked to
. The parameter has one
index for each parameter set-up. The parameter
value displayed for each index represents which
set-ups are linked to that parameter set-up.
Index
LCP value
0
{0}
1
{1,2}
2
{1,2}
3
{3}
4
{4}
Table 3.2 Example: Set-up 1 and Set-up 2 are
linked
0-14 Readout: Edit Set-ups / Channel
Range:
Function:
0
*
[-2147483648 -
2147483647 ]
View the setting of
0-11 Edit Set-up
for each
of the four different communication
channels. When the number is displayed in
hex, as it is in the LCP, each number
represents one channel.
Numbers 1-4 represent a set-up number; ‘F’
means factory setting; and ‘A’ means active
set-up. The channels are, from right to left:
LCP , FC-bus, USB, HPFB1-5.
Example: The number AAAAAA21h means
that the FC bus selected Set-up 2 in
0-11 Edit Set-up
, the LCP selected Set-up 1
and all others used the active set-up.
0-15 Readout: actual setup
Range:
Function:
0
*
[0 - 255 ] Makes it possible to read out the active set-up,
also when multi set-up is selected in par. 0-10.
3.2.3 0-2* LCP Display
Define the variables displayed in the Graphical Local
Control Panel.
NOTE!
Please refer to
0-37 Display Text 1
,
0-38 Display Text 2
and
0-39 Display Text 3
for information on how to write display
texts.
0-20 Display Line 1.1 Small
Option:
Function:
Select a variable for display in
line 1, left position.
[0]
*
None
No display value selected.
[9]
Performance Monitor
[15]
Readout: actual setup
[37]
Display Text 1
[38]
Display Text 2
[39]
Display Text 3
[748]
PCD Feed Forward
[953]
Profibus Warning
Word
[1005]
Readout Transmit
Error Counter
[1006]
Readout Receive
Error Counter
[1007]
Readout Bus Off
Counter
[1013]
Warning Parameter
[1230]
Warning Parameter
[1472]
Legacy Alarm Word
[1473]
Legacy Warning
Word
[1474]
Leg. Ext. Status Word
[1501]
Running Hours
[1502]
kWh Counter
[1600]
Control Word
Present control word
[1601]
Reference [Unit]
Total reference (sum of digital/
analog/preset/bus/freeze ref./
catch up and slow-down) in
selected unit.
[1602]
Reference %
Total reference (sum of digital/
analog/preset/bus/freeze ref./
catch up and slow-down) in
percent.
[1603]
Status Word
Present status word.
[1605]
Main Actual Value
[%]
Actual value as a percentage.
[1609]
Custom Readout
[1610]
Power [kW]
Actual power consumed by the
motor in kW.
[1611]
Power [hp]
Actual power consumed by the
motor in HP.
[1612]
Motor Voltage
Voltage supplied to the motor.
[1613]
Frequency
Motor frequency, i.e., the output
frequency from the Adjustable
frequency drive in Hz
Parameter Descriptions
FC 300 Programming Guide
MG33MD22 - VLT
®
is a registered Danfoss trademark
3-5