9-65 Profile Number
Range:
Function:
0
*
[0 - 0 ] This parameter contains the profile identification.
Byte 1 contains the profile number and byte 2 the
version number of the profile.
NOTE!
This parameter is not visible via LCP.
9-67 Control Word 1
Range:
Function:
0
*
[0 - 65535 ] This parameter accepts the control word from
a Master Class 2 in the same format as PCD 1.
9-68 Status Word 1
Range:
Function:
0
*
[0 - 65535 ] This parameter delivers the status word for a
Master Class 2 in the same format as PCD 2.
9-70 Programming Set-up
Option:
Function:
Select the set-up to be edited.
[0]
Factory setup Uses default data. This option can be used
as a data source to return the other set-ups
to a known state.
[1]
Set-up 1
Edits Set-up 1.
[2]
Set-up 2
Edits Set-up 2.
[3]
Set-up 3
Edits Set-up 3.
[4]
Set-up 4
Edits Set-up 4.
[9]
*
Active Set-up Follows the active set-up selected in
0-10 Active Set-up
.
This parameter is unique to LCP and serial communication
busses. See also
0-11 Programming Set-up
.
9-71 Profibus Save Data Values
Option:
Function:
Parameter values changed via Profibus are not
automatically stored in non-volatile memory.
Use this parameter to activate a function that
stores parameter values in the EEPROM non-
volatile memory, so changed parameter values
will be retained at power-down.
[0]
*
Off
Deactivates the non-volatile storage function.
[1]
Store all
setups
Stores all parameter values for all set-ups in the
non-volatile memory. The selection returns to
Off
[0] when all parameter values have been
stored.
9-71 Profibus Save Data Values
Option:
Function:
[2]
Store all
setups
Stores all parameter values for all set-ups in the
non-volatile memory. The selection returns to
Off
[0] when all parameter values have been
stored.
9-72 ProfibusDriveReset
Option:
Function:
[0]
*
No action
[1]
Power-on
reset
Resets Adjustable frequency drive upon
power-up, as for power-cycle.
[3]
Comm
option reset
Resets the Profibus option only, useful after
changing certain settings in parameter
group 9-**, e.g.,
9-18 Node Address
.
When reset, the Adjustable frequency drive
disappears from the serial communication
bus, which may cause a communication
error from the master.
9-75 DO Identification
Range:
Function:
0
*
[0 - 65535 ] Provides information about the DO (Drive
Object).
9-80 Defined Parameters (1)
Array [116]
No LCP access
Read only
Range:
Function:
0
*
[0 - 9999 ] This parameter displays a list of all the defined
Adjustable frequency drive parameters available
for Profibus.
9-81 Defined Parameters (2)
Array [116]
No LCP access
Read only
Range:
Function:
0
*
[0 - 9999 ] This parameter displays a list of all the defined
Adjustable frequency drive parameters available
for Profibus.
9-82 Defined Parameters (3)
Array [116]
No LCP access
Read only
Range:
Function:
0
*
[0 - 9999 ] This parameter displays a list of all the defined
Adjustable frequency drive parameters available
for Profibus.
Parameter Descriptions
FC 300 Programming Guide
MG33MD22 - VLT
®