Operating variable:
Unit:
16-85 FC Port CTW 1
hex
16-86 FC Port REF 1
hex
16-90 Alarm Word
16-92 Warning Word
16-94 Ext. Status Word
Status screen I
This readout state is standard after start-up or initialization.
Use [INFO] to obtain information about the measurement
links to the displayed operating variables (1.1, 1.2, 1.3, 2
and 3).
See the operating variables shown in the screen below.
1.1
2
3
1.3
1.2
130BP041.10
799 RPM
Auto Remote Ramping
1 (1)
36.4 kW
7.83 A
0.000
53.2%
Status
Status screen II
See the operating variables (1.1, 1.2, 1.3 and 2) shown in
the screen below.
In the example, Speed, Motor current, Motor power and
Frequency are selected as variables in the first and second.
1.1
1.2
2
1.3
130BP062.10
207RPM
Auto Remote Running
1 (1)
24.4 kW
5.25A
6.9Hz
Status
Status screen III
This state displays the event and action of the Smart Logic
Control. For further information, see section
Smart Logic
Control
.
130BP063.10
778 RPM
Auto Remote Running
1 (1)
4.0 kW
0.86 A
State: 0 off 0 (off)
When: -
Do: -
Status
2.1.6 Parameter Set-up
The Adjustable frequency drive can be used for practically
all assignments, which is why the number of parameters is
quite large. The Adjustable frequency drive offers a choice
between two programming modes - a Main Menu and a
Quick Menu mode.
The former provides access to all parameters. The latter
takes the user through a few parameters making it
possible to start operating the Adjustable frequency drive.
Regardless of the mode of programming, you can change
a parameter both in the main menu and quick menu
modes.
2.1.7 Quick Menu Key Functions
Pressing [Quick Menus] The list indicates the different
areas contained in the Quick menu.
Select
My Personal Menu
to display the chosen personal
parameters. These parameters are selected in
0-25 My
Personal Menu
. Up to 20 different parameters can be
added in this menu.
Select
Quick set-up
to go through a limited amount of
parameters to get the motor running almost optimally. The
default setting for the other parameters considers the
desired control functions and the configuration of signal
inputs/outputs (control terminals).
Parameters are selected by using the arrow keys. The
parameters in the following table are accessible.
How to Program
FC 300 Programming Guide
MG33MD22 - VLT
®
is a registered Danfoss trademark
2-5