LCP keys
Description
Press [Status] for selecting the mode of display or for changing back to display mode from either the quick menu
mode, the main menu mode, or the alarm mode. Also use [Status] to toggle single or double readout mode.
[Quick
Menu]
Allows quick access to different quick menus such as:
My personal menu
Quick set-up
Changes made
Loggings
Press [Quick Menu] to program the parameters belonging to the Quick Menu. It is possible to switch directly be-
tween quick menu mode and main menu mode.
[Main
Menu]
Is used for programming all parameters. It is possible to switch directly between main menu mode and quick menu
mode. Parameter shortcut can be carried out by pressing down [Main Menu] for 3 s. The parameter shortcut allows
direct access to any parameter.
[Alarm
Log]
Shows an alarm list of the 5 latest alarms (numbered A1– A5). To obtain extra details about an alarm, press the
navigation keys to maneuver to the alarm number and press [OK]. Information about the condition of the drive
before it enters the alarm mode is shown.
[Back]
Returns to the previous step or layer in the navigation structure.
[Cancel]
Last change or command is canceled as long as the display has not been changed.
[Info]
Supplies information about a command, parameter, or function in any display window. [Info] provides detailed in-
formation whenever help is needed. Exit Info mode by pressing either [Info], [Back], or [Cancel].
Naviga-
tion keys
The 4 navigation keys are used to navigate between the different options available in Quick Menu, Main Menu, and
Alarm Log. Press the keys to move the cursor.
[OK]
Press to select a parameter marked by the cursor and to enable the change of a parameter.
Local control keys:
Local control keys are at the bottom of the control panel.
Table 5: Local Control Keys and Description
LCP
keys
Description
[Hand
On]
Enables control of the drive via the LCP.
[Hand On] also starts the motor, and it is now possible to enter the motor speed data with the navigation keys. The
key can be selected as
[1] Enable
or
[0] Disable via parameter 0-40 [Hand on] Key on LCP
.
External stop signals activated with control signals or a fieldbus override a start command via the LCP.
The following control signals are still active when [Hand On] is activated:
[Hand on] - [Off] - [Auto On]
Reset
Coast stop inverse
Reversing
Set-up select bit 0 - Set-up select bit 1
Stop command from serial communication
Quick stop
DC brake
[Off]
Stops the connected motor. The key can be selected as
[1] Enable
or
[0] Disable via parameter 0-41 [Off] Key on LCP
.
AU373327181955en-000101 / 130R1208 | 21
Danfoss A/S © 2021.08
How to Program
VLT® AutomationDrive EZ FC 321
Programming Guide