5
VLT type
3502
3504
3508
3511
3516
3522
3532
3542
3552
3562
Output current
I
VLT,N
[A]
5.4
10.6
25.0
32.0
46.0
61.0
88.0
104.0 130.0 154.0
I
VLT, MAX
(60 s) [A]
5.9
11.7
27.3
35.2
50.6
67.3
96.8
114.4 143.0 169.0
Output
S
VLT, N
[kVA]
1.9
4.0
10.0
12.7
18.3
24.3
35.1
41.4
51.8
61.3
Typical shaft output
P
VLT, N
[HP]
1
3
5
10
15
20
30
40
50
60
Max. cable cross-section
[AWG]
12
12
6
6
6
4
4
2/0
2/0
2/0
Max. motor cable length
[feet]
1000 (unshielded)*
Output voltage
V
M
[%]
1-100, of AC line voltage
Output frequency
f
M
[Hz]
0-120
Rated motor voltage
V
M, N
[V]
200/220/230
Rated motor frequency
f
M, N
[Hz]
50/60/87/100
Thermal protection during operation
Integrated thermal motor protection (electronic); thermistor to DIN44081
Switching on output
Unlimited (frequent switching may cause cut-out)
Ramp times
[s]
0.1-3600
VLT type
3502
3504
3508
3511
3516
3522
3532
3542
3552
3562
Max. input current
I
L, N
[A]
5.4
10.6
23.1
29.6
42.0
56.8
72.3
102.0 128.0 152.0
Max. cable cross-section
[AWG]
12
12
6
6
6
4
4
2/0
2/0
2/0
Max. pre-fuses
[A]
25
25
40
50
60
80
125
1)
150
2)
150
2)
150
2)
Supply voltage
[V]
3 phase 200/220/230
±
10%
Supply frequency
[Hz]
50/60
Power factor / cos
0.9/1.0
Efficiency
0.96 at 100% load
Switching on input
times/min.
2
Radio noise, cable borne
VLT type 3502-04: EN 55011, class A, gr. 1, with option class B. gr 1
(with shielded cables)
VLT type 3508-32 with option: EN 55011, cl. A, 1 VDE 0875, part 3, curve N
VLT type
3502
3504
3508
3511
3516
3522
3532
3542
3552
3562
Weight (lbs)
Chassis (IP00)
16
16
–
–
–
–
–
–
–
–
and
NEMA 1 (IP 20)
–
–
53
57
70
108
112
315
319
323
enclosure type
NEMA 1 (IP 21)
18
18
–
–
–
–
–
–
–
–
NEMA 12 (IP 54)
24
24
75
81
106
139
143
315
319
323
Power loss
Front
–
–
–
–
–
–
–
357
394
409
at max. load [W]
Heat sink
–
–
–
–
–
–
–
588
712
884
Total
60
130
425
580
651
929
1350
945
1106
1293
Vibration test
[g]
0.7
Relative humidity
[%]
VDE 0160 5.2.1.2.
Ambient temperature
[
°
C]
–10
➔
+40. operation at full load
1)
–30/25
➔
+65/70, storage/transport
Adjustable frequency drive protection
Protection against grounding and short-circuiting
EMC standards
Emission
EN 50011, VDE 0875 part 3
Immunity EN 50082-2, IEC 801-2, IEC 801-3, IEC 801-4, IEC 801-5, VDE 0160, SEN 361503
* If shielded cable is to be used, consult Danfoss for cable length.
1) In the range –10 to 0
°
C, the equipment can start and run; however, the display values and certain operating characteristics will
not fulfill the specifications.
2) Bussmann rapid type JJS integrated.
VLT
®
Series 3500
3 Phase, 200/220/230 Volt, Units