7. Loosen the screw in the coupling using
a 4 mm allen key for a “European
coupling”. Carefully remove the coupling
without damaging the shaft (sometimes a
puller is needed). Remove the key in
the shaft.
2. If the shaft seal flange can’t be removed
easily, screw in 2 x M8 bolts which will
push out the shaft seal flange.
1. Disassemble the shaft seal flange by
unscrewing the 4 bolts using a 6 mm
allen key or socket.
3. Lubricate the Shaft seal with clean filtered
water and carefully remove the shaft seal
using 2 screwdrivers.
4. Unscrew the 15 bolts from the motor
flange using a 10 mm allen key or
socket.
3. Disassembling the
booster / vane pump