Service guide
|
Disassembling and Assembling, iSave 50-70
© Danfoss | DCS (im) | 2016.10
22 | 180R9387 | 521B1430 | DKCFN.PI.013.1H.02
15. Remove the ceramic ring of the shaft seal
in the shaft seal cover using a
screwdriver.
14. Press down the shaft seal to the shoulder/
recess of the shaft using the plastic press
bush tool.
13. Only lubricate the new shaft seal with
clean filtered water and mount the shaft
seal over the shaft end with the carbon
ring upwards.
12. Mount the remaining 11 screws in the
motor flange and cross tighten
all
the
screws to the torque according to
exploded view.
11. Check with a 0.05 mm feeler gauge that
there is
no
gap between the motor flange
and stator housing. If there is a gap loosen
one or more screws and retighten them
again.
16. Lubricate the new shaft seal with clean
filtered water and press the new ceramic
ring into the shaft seal cover using the
plastic press bush tool.
Warning:
Ensure that the face with rubber seal is
positioned against shoulder/recess
in shaft seal cover and the
ceramic ring upwards.