Service guide
|
Disassembling and Assembling, iSave 50-70
© Danfoss | DCS (im) | 2016.10
24 | 180R9387 | 521B1430 | DKCFN.PI.013.1H.02
23. Carefully lower it onto the iSave ( turn the
electrical motor coupling using a
screwdriver through the inspection hole in
the bell housing so it fits into the spider
and the other coupling).
25. Lubricate the screws.
Mount the 4 screws and
washers and tighten to the torque
according tothe drawings in chapter 10
and 11.
26. Remove the lifting straps. Mount all hoses
or pipes to the iSave connectors and
connect the electric cables correctly again.
24. Check through the inspection hole in the
bell housing that the coupling distance
still has 3 - 5 mm free space.
3 - 5 mm
Also remember to retighten all the screws and
nuts on the base frame with the torque accord-
ing to chapter 10 and 11.