Service guide
|
Disassembling and Assembling, iSave 50-70
© Danfoss | DCS (im) | 2016.10
180R9387 | 521B1430 | DKCFN.PI.013.1H.02 | 3
2. Disconnect the isave
from the electric motor
1. For the vertical version mounted on
the Danfoss base frame, safely mount
lifting straps around the electrical motor
to ensure straight vertical lifting. See
Operation guide, chapter 4.
3. Carefully lift the electrical motor straight
up and away from the iSave.
Place the electrical motor safely horizontal
or vertically between 2 brackets.
(
Don’t place it on the coupling ! ! !
)
2. Unscrew the 4 bolts on the electrical
motor using a 24 mm wrench.
4. Unscrew the 4 bolts inside the bell
housing and remove the bolts and
washers using a 19 mm socket and
extension tool.
5. Carefully remove the bell housing from the
iSave.
6. Measure the distance between shaft seal
flange and the coupling to be able to
reassemble it back to the same distance.