Service guide
|
Disassembling and Assembling, iSave 50-70
© Danfoss | DCS (im) | 2016.10
180R9387 | 521B1430 | DKCFN.PI.013.1H.02 | 5
5. Mount 2 x eyebolts in 2 of the M12 holes
and carefully remove the motor flange
and place it carefully with the bearing side
upwards.
6. Visually check the side plate, rotor stop
and motor flange surface for wear and
scratches.
7. Remove the rotor stop by hand only using
a M8 screw.
8. Carefully remove the side plates using a
small screwdriver.
9. Check the rotor stop thickness using a
micrometer. Replace if below 10,80 mm.
10. Check the side plates thickness using a
micrometer. Replace if below 11.55 mm.