24. Turn the pump with shaft upwards.
Lubricate the shaft and shaft seal with
clean filtered water. Mount the shaft
seal with the carbon ring upwards.
25. Using the shaft tool provided,
carefully press down the shaft
seal to the shoulder of the shaft.
27. Mount a new O-ring on the flange
for shaft seal and assemble the minor
flange on top of the flange.
Tighten M8x20 bolts marked A4
to a torque of 30 ±3 Nm.
26. Lubricate and press new ceramic
ring into the shaft seal cover by
using the press bush tool.
WARNING:
Ensure that the face with rubber
seal is positioned against shoulder
in shaft seal flange.
M8x20 bolts marked A4
29. Mount the four special M8x20
bolts marked 1.4410 and tighten
them to a torque of 35 ±3.5 Nm.
28. Mount the two pins and the coupling
part.
4 x special M8x20 bolts
marked 1.4410
Содержание iSave 40
Страница 34: ...Operation guide iSave 40 34 180R9239 AQ299555093252en 001601 iSave 40 09 2022 iSave 40 Code no 180F7011...
Страница 53: ...Operating guide Energy recovery device iSave 40 Appendices hpp danfoss com...
Страница 96: ...M a n u a l Electric Motors Motor Manual hoyermotors com...
Страница 100: ...101 180R9379 AQ188686503004en 000801 PAH 2 12 5 07 2022...