Operation guide | iSave 40
29
180R9239 | AQ299555093252en-001601 | iSave 40 | 09.2022
8. Turn of the pump and allow the elements to
soak.
9. Feed the cleaning solution at high flow into
the “full flow cleaning” adapter (7) on the
feed side of the membrane. The high flow
rate flushes out the foulants removed from
the membrane surface by the cleaning.
10. Flush RO permeate or deionised water into
the “full flow cleaning” adapter (7) on the
feed side of the membrane. Flush out the
cleaning solution. It is essential that the
water used for the final pre-flush is pre-fil-
tered to a level described in the Data sheet.
11. Remove plug (9). Water will flow out of the
iSave and the iSave may start to rotate
backward – this is OK.
12. Continue to flush the iSave until no chemi-
cals are coming out of the iSave.
13. When flushing is finalised – Close the
high- pressure “full flow cleaning” valve (7)
and close valve (16).
14. Connect the high pressure pipe to joint (9)
again.
Normal operation mode
10.3.3 P&ID no. 2
Media filter
M
Permeate
iSave
F
F
F
Flowmeter
v
VFD
M
HP in
HP out
VFD
M
HP in
HP out
VFD
Fresh water
permeate flush
Full flow
cleaning/CIP
6
7
17
8
15
13
10
11
11
12
19
Filter
3 micron
nominel
Filter
10 micron
absolut
Drain
4
18
5
M
4
18
VFD
LP in
20
F
*
*
Second stage filter:
If recommended housing design and cartridges are not used, a second stage filter is required
1
21
2
PS
PI
PS
PI
PS
14
PI
PI
PI
PI
PI
3
A
B
C
22
22
PS
24
23
23
25
25
26
26
9
27
CIP
28
16
Membrane cleaning mode
Media filter
M
Permeate
iSave
F
F
F
Flowmeter
VFD
M
HP in
HP out
VFD
M
HP in
HP out
VFD
Fresh water
permeate flush
Full flow
cleaning/CIP
6
7
17
8
15
13
10
11
11
12
19
Filter
3 micron
nominel
Filter
10 micron
absolut
Drain
4
18
5
M
4
18
VFD
LP in
20
F
*
*
Second stage filter:
If recommended housing design and cartridges are not used, a second stage filter is required
1
21
2
PS
PI
PS
PI
PS
14
PI
PI
PI
PI
PI
3
A
B
C
22
22
PS
24
23
23
25
25
26
26
9
27
CIP
28
16
Filter
5 micron
nominel
Filter
5 micron
nominel
Содержание iSave 40
Страница 34: ...Operation guide iSave 40 34 180R9239 AQ299555093252en 001601 iSave 40 09 2022 iSave 40 Code no 180F7011...
Страница 53: ...Operating guide Energy recovery device iSave 40 Appendices hpp danfoss com...
Страница 96: ...M a n u a l Electric Motors Motor Manual hoyermotors com...
Страница 100: ...101 180R9379 AQ188686503004en 000801 PAH 2 12 5 07 2022...