180R9239 | AQ299555093252en-001601 | iSave 40 | 09.2022
Instruction | Right and wrong - Hose assembly routing tips
6
180R9434 | AN375455762639en-000201 | 07.2021
3.
Hose specification
table
α
r
O.D.
S
S
When using flexible hoses, it is
recommened to use Hose Whip Restraint.
High pressure hoses
Code
number
Pipe connection
1
)
[A]
Pipe
connection
material
Hose size
Inner
diameter
Hose length
ISO 1436
[B]
Bending radius
S
180Z0228
1.5" Vic. OGS
Super duplex
EN 1.4410
25.4 mm (1.0") 0.66 m (26")
152 mm (6.08"), max. 90°
79 mm (3.11”)
180Z0229
1.5" Vic. OGS
Super duplex
EN 1.4410
25.4 mm (1.0") 1.16 m (45.7") 152 mm (6.08"), max. 180°
79 mm (3.11”)
180Z0167
1.5" Vic. OGS
Super duplex
EN 1.4410
38.0 mm (1.5") 1.16 m (45.7") 250 mm (9.84"), max. 180°
85 mm (3.35”)
180Z0140
2.0" Vic. OGS
Super duplex
EN 1.4410
50 mm (2.0")
1.25 m (49")
630 mm (24.8"), max. 90°
115 mm (4.53”)
180Z0263
2.5" Vic. OGS
)
Super duplex
EN 1.4410
50 mm (2.0")
1.78 m (70")
630 mm (24.8"), max. 180°
115 mm (4.53”)
180Z0280
2.5" Vic. OGS
Super duplex
EN 1.4410
50 mm (2.0")
1.00 m (39.4") 630 mm (24.8"), max. 90°
115 mm (4.53”)
180Z0619
2.5" Vic. OGS
Super duplex
EN 1.4410
65 mm (2.5")
1.78 m (70")
200 mm (7.87"), max. 270°
150 mm (5.90”)
180Z0618
2.5" Vic. OGS
Super duplex
EN 1.4410
65 mm (2.5")
1.00 m
(9.4")
200 mm (7.87"), max. 90°
150 mm (5.90”)
180Z0612
3.0" Vic. OGS
Super duplex
EN 1.4410
76 mm (3.0")
1.79 m (70.5") 250 mm (9.84"), max. 270°
150 mm (5.90”)
180Z0611
3.0" Vic. OGS
Super duplex
EN 1.4410
76 mm (3.0")
1.00 m (39.4") 250 mm (9.84"), max. 90°
150 mm (5.90”)
180Z1000
3.0" Vic. OGS
Super duplex
EN 1.4410
76 mm (3.0")
1,25 m (49")
250 mm (9.84"), max. 180°
150 mm (5.90”)
180Z1001
3.0" Vic. OGS
Super duplex
EN 1.4410
76 mm (3.0")
1,6 m (63")
250 mm (9.84"), max. 180°
150 mm (5.90”)
Low pressure hoses
180Z0298
2.0” Vic. OGS
Super duplex
EN 1.4410
2.0 m
(79”)
180Z0144
3.0” Vic. OGS
Super duplex
EN 1.4410
2.0 m
(79”)
1)
The installation instuction for Style 77DX is located in the Victaulic document I-100 Field Installation Handbook (htpp://static.victaulic.com)
Содержание iSave 40
Страница 34: ...Operation guide iSave 40 34 180R9239 AQ299555093252en 001601 iSave 40 09 2022 iSave 40 Code no 180F7011...
Страница 53: ...Operating guide Energy recovery device iSave 40 Appendices hpp danfoss com...
Страница 96: ...M a n u a l Electric Motors Motor Manual hoyermotors com...
Страница 100: ...101 180R9379 AQ188686503004en 000801 PAH 2 12 5 07 2022...