![background image](http://html1.mh-extra.com/html/danfoss/isave-40/isave-40_operation-manual_3540938062.webp)
Operation guide | iSave 40
62
180R9239 | AQ299555093252en-001601 | iSave 40 | 09.2022
1.
Install the locking tool to prevent the
shaft from rotating.
3.
Place the vanepump on a clean surface
in the vertical position with the shaft
pointing upwards. Remove the key
and the dust cap from the shaft.
3. 1 Disassembling the
booster pump series
04 and newer
4.
Remove the four screws in the shaft
seal cover.
6.
Wet the shaft seal with clean filtered
water, carefully lift the shaft seal by
using two screwdreivers.
2.
Remove the coupling by unscrewing
the four special M8 x 20 bolts marked
with 1.4410
5.
Remove cover for shaft seal. If it cannot
be removed easily, use two M8 bolts to
push it straight out.