![background image](http://html1.mh-extra.com/html/danfoss/isave-40/isave-40_operation-manual_3540938026.webp)
Operation guide | iSave 40
26
180R9239 | AQ299555093252en-001601 | iSave 40 | 09.2022
600
1200
700
650
750
800
850
900
950
1050
1000
1100
1150
18
20
22
24
26
28
30
32
34
36
38
40
176
132
gpm
88
rpm
42
m
3
/h
-10%
10%
-8%
-6%
-4%
-2%
0
2%
4%
6%
8%
12
%
10
8
6
4
2
0
Underflushing
Overflushing
P&ID
Mixing curve
Flow curve iSave 40
Media filter
M
Permeate
iSave
F
F
1
F
Flowmeter
VFD
M
HP in
HP out
VFD
Fresh water
permeate flush
Full flow
cleaning
6
17
8
9
16
15
13
14
10
11
12
19
Filter
3 micron
nominel
Filter
10 micron
absolut
Drain
2
4
18
5
LP in
20
F
*
*
Second stage filter:
If recommended housing design and cartridges are not used, a second stage filter is required
PI
PI
PI
PI
PI
PS
PS
7
3
PS
PI
CIP
27
28
Filter
5 micron
nominel