FCM 300 Series
41
MG.03.B6.02 - VLT is a registered Danfoss trademark
✭
=
factory setting. ( ) = display text [ ] = value for use in communication via serial communication port
Operation & Display
Frequency x Scaling
Frequency x Scaling
Frequency x Scaling
Frequency x Scaling
Frequency x Scaling
[-]
[-]
[-]
[-]
[-] corresponds to the present
motor frequency f
M
multiplied by a factor (scaling) set
in parameter 008.
Motor current
Motor current
Motor current
Motor current
Motor current
[A]
[A]
[A]
[A]
[A] states the phase current of the
motor measured as effective value.
T
T
T
T
Torque
orque
orque
orque
orque
[%]
[%]
[%]
[%]
[%] gives the current motor load in relation
to the rated motor torque.
Power
Power
Power
Power
Power
[kW]
[kW]
[kW]
[kW]
[kW] states the actual power consumed by
the motor in kW.
Power
Power
Power
Power
Power
[HP]
[HP]
[HP]
[HP]
[HP] states the actual power consumed by
the motor in HP.
Motor voltage
Motor voltage
Motor voltage
Motor voltage
Motor voltage
[V]
[V]
[V]
[V]
[V] states the voltage supplied to the
motor.
DC link voltage
DC link voltage
DC link voltage
DC link voltage
DC link voltage
[V]
[V]
[V]
[V]
[V] states the intermediate circuit
voltage in the FC motor.
Thermal load, FC
Thermal load, FC
Thermal load, FC
Thermal load, FC
Thermal load, FC
[%]
[%]
[%]
[%]
[%] states the calculated/estimated
thermal load on the FC motor. 100% is the cut-out
limit.
Hours run
Hours run
Hours run
Hours run
Hours run
[Hours]
[Hours]
[Hours]
[Hours]
[Hours] states the number of hours that
the motor has run since the latest reset in
parameter 619.
Digital input
Digital input
Digital input
Digital input
Digital input
[Binary code]
[Binary code]
[Binary code]
[Binary code]
[Binary code] states the signal states
from the 4 digital terminals (2, 3, 4 and 5). Input 5
corresponds to the bit at the far left. '0' = no signal,
'1' = connected signal.
External reference
External reference
External reference
External reference
External reference
[%]
[%]
[%]
[%]
[%] gives the sum of the external
reference as a percentage (the sum of analogue/
pulse/bus).
Status word
Status word
Status word
Status word
Status word
[Hex]
[Hex]
[Hex]
[Hex]
[Hex] gives the status word sent via
the serial communication port in Hex code from the
FC motor.
Heat sink
Heat sink
Heat sink
Heat sink
Heat sink temp.
temp.
temp.
temp.
temp.
[°C]
[°C]
[°C]
[°C]
[°C] states the present heat sink
temperature of the FC motor. The cut-out limit is 90 ±
5°C; cutting back in occurs at 60 ± 5°C.
Alarm word
Alarm word
Alarm word
Alarm word
Alarm word
[Hex]
[Hex]
[Hex]
[Hex]
[Hex] indicates one or several alarms in
a Hex code. See page 66.
Control word.
Control word.
Control word.
Control word.
Control word.
[Hex]
[Hex]
[Hex]
[Hex]
[Hex] indicates the control word for
the FC motor. See
Serial communication
.
Warning word 1.
Warning word 1.
Warning word 1.
Warning word 1.
Warning word 1.
[Hex]
[Hex]
[Hex]
[Hex]
[Hex] indicates one or more
warnings in a Hex code. See page 66 for further
information.
Warning word 2.
Warning word 2.
Warning word 2.
Warning word 2.
Warning word 2.
[Hex]
[Hex]
[Hex]
[Hex]
[Hex] indicates one or more
status states in a Hex code. See page 66 for further
information.
Analog input 1 [mA]
Analog input 1 [mA]
Analog input 1 [mA]
Analog input 1 [mA]
Analog input 1 [mA]
, states the signal value on
terminal 1.
Analog input 2 [V]
Analog input 2 [V]
Analog input 2 [V]
Analog input 2 [V]
Analog input 2 [V]
, states the signal value on
terminal 2.
010 Display line 1.1 (DISPLAY LINE 1.1)
Value:
✭
Reference [%]
[1]
See parameter 009.
Function:
This parameter enables a choice of the first of three
data values to be shown on the display, line 1,
position 1.
For display read-outs, press the [DISPLAY/STATUS]
button, see also page 28.
Description of choice:
There is a choice of 24 different data values, see
parameter 009.
011 Display line 1.2 (DISPLAY LINE 1.2)
Value:
✭
Motor current [A]
[6]
See parameter 009
Function:
This parameter enables a choice of the second of
the three data values to be shown on the display,
line 1, position 2.
For Display read-outs, press the [DISPLAY/STATUS]
button, see also page 28.
Description of choice:
There is a choice of 24 different data values, see
parameter 009.
012 Display line 1.3 (DISPLAY LINE 1.3)
Value:
✭
Power [kW]
[8]
See parameter 009
Function:
This parameter enables a choice of the third of the
three data values to be shown on the display, line 1,
position 3.
Display read-outs are made by pressing the
[DISPLAY/STATUS] button, see also page 28.
Description of choice:
There is a choice of 24 different data values, see
parameter 009.