FCM 300 Series
57
MG.03.B6.02 - VLT is a registered Danfoss trademark
Off 123 relay
, if Profidrive [0] has been selected in
parameter 512, the output is activated. If either OFF1,
OFF2 or OFF3 (bit in the control word) is logic '1'.
0-f
MAX
(parameter 202)
⇒
0-20 mA
and
0-f
MAX
(parameter 202)
⇒
4-20 mA
Reference
MIN
- Reference
MAX
: 0-20 mA
and
Reference
MIN
- Reference
MAX
: 4-20 mA
Feedback
LOW
- Feedback
HIGH
: 0-20 mA
and
Feedback
LOW
- Feedback
HIGH
: 4-20 mA
0-I
VLT, MAX
⇒
0-20 mA and
0-I
VLT, MAX
⇒
4-20 mA
Mechanical brake
, enables control of an optional
external mechanical brake (see also parameter 138
and 139).
Inputs and Outputs