FC 302
N90K
N110
N132
Control card overtemperature trip [°C (°F)]
75 (167)
75 (167)
75 (167)
PHF overtemperature trip [°C (°F)]
145 (293)
145 (293)
145 (293)
Line reactor overtemperature trip [°C (°F)]
150 (302)
150 (302)
150 (302)
dU/dt filter overtemperature trip [°C (°F)]
150 (302)
150 (302)
150 (302)
Sine-wave filter overtemperature trip [°C (°F)]
150 (302)
150 (302)
150 (302)
1
Typical power loss is at normal conditions and expected to be within ±15% (tolerance relates to variety in voltage and cable conditions.) These
values are based on a typical motor efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the drive. Applies to dimension-
ing of drive cooling. If the switching frequency is higher than the default setting, the power losses can increase. LCP and typical control card power
consumptions are included. For power loss data according to EN 50598-2, refer to drives.danfoss.com/knowledge-center/energy-efficiency-direc-
tive/#/. Options and customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for slots A and B each
add only 4 W.
2
Measured using 5 m (16.4 ft) shielded motor cables at rated load and rated frequency. Efficiency measured at nominal current. For energy efficien-
cy class, see the
Ambient Conditions
section. For part load losses, see drives.danfoss.com/knowledge-center/energy-efficiency-directive/#/.
3
See also
Input Power Option Losses
section.
4
If using an output filter, the output frequency is limited further. See
Table 102: Electrical Data, Mains Supply 3x380–500 V AC
FC 302
N160
N200
N250
High/normal overload
High overload=150% or 160% torque for a duration of 60 s.
Normal overload=110% torque for a duration of 60 s.
HO
NO
HO
NO
HO
NO
Typical shaft output at 400 V [kW]
160
200
200
250
250
315
Typical shaft output at 460 V [hp]
250
300
300
350
350
450
Typical shaft output at 500 V [kW]
200
250
250
315
315
355
Enclosure size
D10h
D10h
D10h
Output current (3-phase)
Continuous (at 400 V) [A]
315
395
395
480
480
588
Intermittent (60 s overload) (at 400 V) [A]
473
435
593
528
720
647
Continuous (at 460/500 V) [A]
302
361
361
443
443
535
Intermittent (60 s overload) (at 460/500 V) [A]
453
397
542
487
665
589
Continuous kVA (at 400 V) [kVA]
218
274
274
333
333
407
Continuous kVA (at 460 V) [kVA]
241
288
288
353
353
426
Continuous kVA (at 500 V) [kVA]
262
313
313
384
384
463
Maximum input current
Continuous (at 400 V) [A]
304
381
381
463
463
567
Continuous (at 460/500 V) [A]
291
348
348
427
427
516
Maximum number and size of cables per phase
- Mains [mm
2
(AWG)]
2x185 (2x350 mcm) 2x185 (2x350 mcm) 2x185 (2x350 mcm)
AQ262139143212en-000301 / 130R0879
162 | Danfoss A/S © 2021.10
Specifications
VLT® AutomationDrive FC 302
Operating Guide