Function
The controller has a setting where you can choose between various
types of installation. If you use these settings, the controller will sug-
gest a series of connection points for the different functions. These
points are shown below.
Even if your installation is not 100% as described below, you can still
use the function. After use, you need only adjust the divergent set-
tings.
The given connection points in the controller can be changed if you
wish.
Appendix C -
Recommended connection
Appl.
Compressor
Fan
Description
Module
Point number
Appl.
Point number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
24
25
1
3 x single
4 fan
Module 1 -
Controller
S3
S4
Loadshed
1
Flow
switch
Heat
recovery
Main Sw.
1
Sc3
Sd
Ss
P0
Pc
Comp. 1 Comp. 2 Comp. 3
Liquid
injec-
tion
Pump 1
Pump 2
Module 2 -
AK-XM 102B
Comp. 1
safety
Comp. 2
safety
Comp. 3
safety
Module 3 -
AK-XM 204_
Fan 1
Fan 2
Fan 3
Fan 4
2
4 x single
4 fan
Module 1 -
Controller
S3
S4
Loadshed
1
Flow
switch
Heat
recovery
Main Sw.
2
Sc3
Sd
Ss
P0
Pc
Comp. 1 Comp. 2 Comp. 3 Comp. 4
Liquid
injec-
tion
Pump 1
Pump 2
Module 2 -
AK-XM 102B
Comp. 1
safety
Comp. 2
safety
Comp. 3
safety
Comp. 4
safety
Module 3 -
AK-XM 204_
Fan 1
Fan 2
Fan 3
Fan 4
3
5 x single
6 fan
Module 1 -
Controller
S3
S4
Loadshed
1
Flow
switch
Heat
recovery
Main Sw.
3
Sc3
Sd
Ss
P0
Pc
Comp. 1 Comp. 2 Comp. 3 Comp. 4 Comp. 5 Liquid
injec-
tion
Pump 1
Pump 2
Module 2 -
AK-XM 102B
Comp. 1
safety
Comp. 2
safety
Comp. 3
safety
Comp. 4
safety
Comp. 5
safety
Module 3 -
AK-XM 204_
Fan 1
Fan 2
Fan 3
Fan 4
Fan 5
Fan 6
4
6 x single
6 fan
Module 1 -
Controller
S3
S4
Loadshed
1
Flow
switch
Heat
recovery
Main Sw.
4
Sc3
Sd
Ss
P0
Pc
Comp. 1 Comp. 2 Comp. 3 Comp. 4 Comp. 5 Comp. 6 Pump 1
Pump 2
Module 2 -
AK-XM 102B
Comp. 1
safety
Comp. 2
safety
Comp. 3
safety
Comp. 4
safety
Comp. 5
safety
Comp. 6
safety
Module 3 -
AK-XM 204_
Fan 1
Fan 2
Fan 3
Fan 4
Fan 5
Fan 6
Liquid
injec-
tion
5
1 x 1 unload
2 x single
4 fan
Module 1 -
Controller
S3
S4
Loadshed
1
Flow
switch
Heat
recovery
Main Sw.
5
Sc3
Sd
Ss
P0
Pc
Comp. 1 Comp. 1
Unload.
1
Comp. 2 Comp. 3
Liquid
injec-
tion
Pump 1
Pump 2
Module 2 -
AK-XM 102B
Comp. 1
safety
Comp. 2
safety
Comp. 3
safety
Module 3 -
AK-XM 204_
Fan 1
Fan 2
Fan 3
Fan 4
6
1 x 1 unload
3 x single
4 fan
Module 1 -
Controller
S3
S4
Loadshed
1
Flow
switch
Heat
recovery
Main Sw.
6
Sc3
Sd
Ss
P0
Pc
Comp. 1 Comp. 1
Unload.
1
Comp. 2 Comp. 3 Comp. 4 Liquid
injec-
tion
Pump 1
Pump 2
Module 2 -
AK-XM 102B
Comp. 1
safety
Comp. 2
safety
Comp. 3
safety
Comp. 4
safety
Module 3 -
AK-XM 204_
Fan 1
Fan 2
Fan 3
Fan 4
7
1 x 2 unload
2 x single
4 fan
Module 1 -
Controller
S3
S4
Loadshed
1
Flow
switch
Heat
recovery
Main Sw.
7
Sc3
Sd
Ss
P0
Pc
Comp. 1 Comp. 1
Unload.
1
Comp. 1
Unload.
2
Comp. 2 Comp. 3 Liquid
injec-
tion
Pump 1
Pump 2
Module 2 -
AK-XM 102B
Comp. 1
safety
Comp. 2
safety
Comp. 3
safety
Module 3 -
AK-XM 204_
Fan 1
Fan 2
Fan 3
Fan 4
8
1 x 2 unload
3 x single
4 fan
Module 1 -
Controller
S3
S4
Loadshed
1
Flow
switch
Heat
recovery
Main Sw.
8
Sc3
Sd
Ss
P0
Pc
Comp. 1 Comp. 1
Unload.1
Comp. 1
Unload.2
Comp. 2 Comp. 3 Comp. 4 Pump 1
Pump 2
Module 2 -
AK-XM 102B
Comp. 1
safety
Comp. 2
safety
Comp. 3
safety
Comp. 4
safety
Module 3 -
AK-XM 204_
Fan 1
Fan 2
Fan 3
Fan 4
Liquid
injection
9
3 x 1 unload
6 fan
Module 1 -
Controller
S3
S4
Loadshed
1
Flow
switch
Heat
recovery
Main Sw.
9
Sc3
Sd
Ss
P0
Pc
Comp. 1 Comp. 1
Unload.1
Comp. 2 Comp. 2
Unload.1
Comp. 3 Comp. 3
Unload.1
Pump 1
Pump 2
Module 2 -
AK-XM 102B
Comp. 1
safety
Comp. 2
safety
Comp. 3
safety
Module 3 -
AK-XM 204_
Fan 1
Fan 2
Fan 3
Fan 4
Fan 5
Fan 6
Liquid
injec-
tion