Configuration & control of the AC SuperDrive
26.04.2005
6.14 H
OW THE
AC S
UPER
D
RIVE HANDLES PARAMETERS
6.14.1 G
ENERAL
Parameters are stored in EEPROM memory, which provides non-volatile storage with the
capability to change parameter values.
Figure 33. Parameter Access and Flow.
organization of AC SuperDrive memory and the paths over which parameter flow.
Figure 33. Parameter Access and Flow.
6.14.2 P
ARAMETER VERIFICATION AT STARTUP
Upon power up (when power is applied to the
KEYSTART
input) drive software copies parameter
values from EEPROM memory into a segment of RAM memory reserved for parameters. The
operating software then performs several checks to verify the validity of the parameter set in
RAM. The parameters set is considered invalid whenever any of the following discrepancies are
detected.
•
ACS Id (from connector K1-8 & K1-9)
≠
ACS Id (read from EEPROM)
•
Application SW Build Time (read from Flash Memory)
≠
Application SW Build Time (read from
EEPROM)
•
Parameter checksum error.
When an invalid set of parameters is detected, the AC SuperDrive operating software performs
the following actions:
•
Copies default parameters from flash memory into RAM.
•
Updates ACS Id from connector K1.
Item No.
89Y05120A
User's Guide 1.0
66
Содержание SuperDrive ACS24 Series
Страница 12: ......
Страница 34: ......
Страница 38: ......
Страница 79: ...26 04 2005 Troubleshooting guide User s Guide 1 0 Item No 89Y05120A 79...
Страница 81: ...26 04 2005 Troubleshooting guide User s Guide 1 0 Item No 89Y05120A 81...
Страница 82: ...Troubleshooting guide 26 04 2005 Item No 89Y05120A User s Guide 1 0 82...
Страница 86: ...Troubleshooting guide 26 04 2005 7 7 11 CAN TIME OUT Error Code 0x8100 Item No 89Y05120A User s Guide 1 0 86...
Страница 92: ......