Internal Image Test Patterns
The Genie camera includes a built in test pattern generator that can be used to confirm
camera Ethernet connections or driver installations, without the need for a camera lens or
proper lighting. The pattern generator inserts video just after the sensor A/D converter,
therefore Genie processing such as the LUT act on the generator images or on sensor
images.
CamExpert is used to easily enable and select the Genie test patterns. As shown in the
following figure, select the Sensor tab, then select one of the four patterns from the drop
menu. Select live grab to see the pattern output.
Genie Test Pattern Selection – on Sensor Tab
The Genie test patterns are:
•
Horizontal ramp: successive pixel's gray level is incremented by 1 to maximum pixel
value then repeated until the end of line. The gray level is reset to 0 on the following
line.
•
Vertical ramp: similar to the horizontal ramp, successive lines are incremented by 1
gray level then repeated for the full frame.
•
Moving diagonal ramp: combination of the 2 previous schemes, but first pixel in image
is incremented by 1 between successive frames. This is a good pattern to indicate
motion when doing a continuous grab.
•
Purity: a purity pattern where all pixels have the same value. The gray value is
incremented by one on successive frames to maximum then repeated. This also provides
motion for live grabs.
Genie Monochrome Series-GigE Vision Camera
Operational Reference
•
75