Genie Signal Electrical Details
•
Power Supply (pin 2): +12V DC nominal at 0.5 Amp minimum.
(see Camera Performance Specifications)
Over voltage and reverse voltage protection circuit built in. The protection circuit is reset
by shutting down or disconnecting the power supply.
•
The 12-pin Hirose male connector shell and cable shield should connect to the supply
earth ground to improve EMI and ESD shielding.
External Inputs
•
Opto-coupled (2V to 12V, 2mA minimum) with internal current limit.
•
RS422 or TTL signal type (see figures below).
•
24 Volt signals supported with additional external current limiting (see figure below).
•
Used as trigger or integration control.
•
External signal polarity selected via configuration parameter.
•
User programmable debounce time from 1 to 255µs.
•
See "Input Controls via Sapera LT or GigE Vision Compliant Applications" on page 61.
The opto-coupler is typically a Fairchild HMHA281 with the following characteristics.
Input Electrical Parameter Description
Value
Voltage threshold to turn OFF
0.8 V
Voltage threshold to turn ON
2 V
Minimum input current to turn ON
2 mA
Maximum input current
50 mA
Minimum input pulse width to turn ON
30 µs
Output rise time (typical)
10 µs
Output fall time (typical)
50 µs
Maximum input voltage
13 V
Maximum reverse voltage
- 6 V
Genie Monochrome Series-GigE Vision Camera
Technical Specifications
•
113