Read Only Parameters
Parameter
Description
Device Vendor
For the Genie Monochrome series, this is always DALSA.
Device Model Name
Displays the device model name (for example, Genie M640).
Device Version
Displays the device version which includes the firmware release and build..
Firmware Version
Displays the currently loaded firmware version manufacturer's code.
Device ID
Displays the camera serial number.
MAC Address
Displays the unique MAC (Media Access Control) address of the Genie
camera.
User Set Parameters
Parameter
Description
Device User ID
Specifies a user written ID, of up to 15 characters, for the Genie camera.
By default, this field is set to the serial number of the camera.
Power-up
Configuration
Click Setting to open the Power-up configuration dialog box which
allows you to specify camera power-up configuration. For more information,
see "Power-up Configuration" on page 37.
Power-up Configuration (Saved User Settings)
The Power-up configuration dialog allows you to specify the camera configuration to load
when powering-up the camera. The Genie camera flash memory contains two possible
configuration settings; the Factory Default (neutral parameters and in free run mode), and a
user-defined Camera Configuration 1. The Camera Power-up configuration drop-down
list box allows you to select either the Factory Default or a user specified camera
configuration file. To save the current CamExpert settings to the camera user-defined
(Camera Configuration) setting, click Save. To view in CamExpert a camera configuration
file currently saved in the camera, select the configuration file in the Load configuration
from Camera drop-down list, and click Load. See the parameter list below.
Genie Monochrome Series-GigE Vision Camera
Operational Reference
•