background image

C/CS-Mount NIR and UV Filter 

Midwest Optical Systems has available a C-mount NIR/UV filter. This filter screws into the 

Genie camera before mounting the lens. The figures below show the filter before mounting 

into the Genie, followed by the filter physical specifications and pass spectrum. Contact 

Midwest Optical Systems directly for technical information and pricing.  

   

 

 

Physical 
Specifications:  

Outside diameter: 25.4mm, 32 NS2A thread (c-mount 

thread)  

Clear Aperture: 19.5mm 

Thickness: 3.0 ±0.1mm  

0.00

10.00

20.00

30.00

40.00

50.00

60.00

70.00

80.00

90.00

100.00

350

450

550

650

750

850

950

1050

Transmission (%)

Wavelength (nm)

BP550 UV + NIR BLOCK/VISIBLE PASS

 

 

For Information 
contact:  

Midwest Optical Systems 

322 Woodwork Ln. 

Palatine Il. 60067 USA 

Tel: 847-359-3550 

http://www.midwestopticalsystems.com/  

124  

  Technical Specifications 

Genie Monochrome Series-GigE Vision Camera 

Содержание Genie Monochrome Series

Страница 1: ...erutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In st...

Страница 2: ...nochrome Series Camera User s Manual Genie Framework 2 01 M640 M690 M1024 M1280 M1400 M1410 M1600 sensors cameras frame grabbers processors software vision solutions P N CA GENM NM MUM00 www teledyned...

Страница 3: ...ndows 8 and Windows 8 1 are trademarks of Microsoft Corporation All other trademarks or intellectual property mentioned herein belong to their respective owners Document Date April 15 2015 Document Nu...

Страница 4: ...ING INSTRUCTIONS 21 GIGE NETWORK ADAPTER GUIDELINE 21 Supported Network Configurations 21 INSTALLATION OVERVIEW PREPARATIONS 22 Network and Computer Overview 22 Installation Overview 23 Preventing Ope...

Страница 5: ...GENERAL INPUTS 59 External Input Signal Opto coupler Debounce Circuit 59 General Inputs Settings Via CamExpert 60 Input Controls via Sapera LT or GigE Vision Compliant Applications 61 STROBE AND GENER...

Страница 6: ...IFICATION 111 CONNECTORS 112 12 Pin Hirose Connector Signal Details 112 Genie Signal Electrical Details 113 RJ45 LAN Ethernet Connector Details 116 CAMERA STATUS LED 116 OPTICAL CONSIDERATIONS 117 Ill...

Страница 7: ...EVICE AVAILABLE WITH OPERATIONAL ISSUES 133 Firmware Updates 133 Power Failure During a Firmware Update Now What 133 Cabling and Communication Issues 134 Acquisition Error without Timeout Messages 135...

Страница 8: ...a LT software libraries featuring CamExpert for simplified camera set up and configuration Sapera LT is field proven in thousands of robust industrial applications Hardware independent Sapera LT deliv...

Страница 9: ...ers the monochrome Genie models summarized below See Camera Performance Specifications on page 10 for each Genie model Camera Sensor Size Resolution Pixel size m fps full frame Product Number Genie M6...

Страница 10: ...Sapera documentation in compiled HTML help and Adobe Acrobat PDF formats OC SL00 0000000 sold separately Sapera Processing Imaging Development Library sold separately Includes over 600 optimized image...

Страница 11: ...al timer or external signal to timestamp images and events Test image Internal pattern generator User settings Select factory default or one user camera configuration Optical Interface Back Focal Dist...

Страница 12: ...mera part numbers CR GENx xxxxx Vibration and Shock Certifications Test while operating Standard Description Sinusoidal vibrations with identification of critical frequencies IEC 68 2 6 1995 Test Fc F...

Страница 13: ...file respecting the syntax defined by the GenApi module of the GenICam specification For more information see www genicam org Genie Sensor Overview Each sensor description below provides a specificati...

Страница 14: ...10 seconds Maximum Frame Rate free running 64 fps Minimum Exposure 22 s Maximum Exposure 16 seconds note maximum exposures are susceptible to hot pixel noise Internal Trigger to Start of Exposure 3 8...

Страница 15: ...ds Maximum Frame Rate free running 64 fps 90 fps for M690 Minimum Exposure 22 s Maximum Exposure 16 seconds note maximum exposures are susceptible to hot pixel noise Internal Trigger to Start of Expos...

Страница 16: ...seconds Maximum Frame Rate free running 20 fps Minimum Exposure 44 s Maximum Exposure 16 seconds note maximum exposures are susceptible to hot pixel noise Internal Trigger to Start of Exposure 7 65 s...

Страница 17: ...seconds Maximum Frame Rate free running 24 5 fps Minimum Exposure 13 s Maximum Exposure 16 seconds note maximum exposures are susceptible to hot pixel noise Internal Trigger to Start of Exposure 2 33...

Страница 18: ...onds Maximum Frame Rate free running 15 fps Minimum Exposure 32 s Maximum Exposure 16 seconds note maximum exposures are susceptible to hot pixel noise Internal Trigger to Start of Exposure 11 87 s Ho...

Страница 19: ...onds Maximum Frame Rate free running 21 fps Minimum Exposure 32 s Maximum Exposure 16 seconds note maximum exposures are susceptible to hot pixel noise Internal Trigger to Start of Exposure 4 15 s Hor...

Страница 20: ...fps one frame every 10 seconds Maximum Frame Rate free running 15 fps Minimum Exposure 35 s Maximum Exposure 16 seconds note maximum exposures are susceptible to hot pixel noise Horizontal Line Time...

Страница 21: ...mprehensive set of C classes for image processing and analysis Sapera Processing offers highly optimized tools for image processing blob analysis search pattern recognition OCR and barcode decoding Th...

Страница 22: ...hird party PCI adapters Supported Network Configurations The Genie obtains an IP address using the Link Local Address LLA or DHCP by default A LLA IP address is obtained in about 6 seconds with Micros...

Страница 23: ...ackage user s manual If Genie is to be used in a Sapera development environment Sapera LT needs to be installed either before or after the Genie software package If Genie will be used in a GigE Vision...

Страница 24: ...n See Status LED Codes on page 27 for Genie LED display descriptions Look at the small camera icon added to the Windows tray next to the clock Ensure the Genie camera has been found right click the ic...

Страница 25: ...ed to earth ground and can withstand ESD of 8 kilovolts as tested by Teledyne DALSA Method 2 Mount the Genie camera on a metallic platform which has a good connection to earth ground Sapera LT Library...

Страница 26: ...to install Sapera LT run time which includes CamExpert Follow the on screen prompts and reboot when the installation is complete GigE Server Verification After a successful Genie Framework package in...

Страница 27: ...26 for an overview of the Genie interfaces Connectors The Genie has only two connectors A single RJ45 Ethernet connector for control and video data transmitted to from the host computer Gigabit NIC Se...

Страница 28: ...o link Steady Blue IP address assigned no application connected to the camera Steady Green Application connected Slow Flashing Green Triggered acquisition in progress Fast Flashing Green Free running...

Страница 29: ...lue the GigE server tray icon will not have a red X through it indicating that the Genie device was found It might take a few seconds for the GigE Server to refresh its state after the Genie has obtai...

Страница 30: ...or any NIC not used with a GigE Vision camera Change the Auto Discovery Interval from the default of 15 seconds Configure the Windows firewall exception list Configure the NIC and camera IP settings A...

Страница 31: ...are by following this procedure Important Make sure that no Sapera application such as CamExpert is controlling the Genie camera Start the Teledyne DALSA Device Manager program from the windows start...

Страница 32: ...in then run CamExpert to test the Genie operation as described below Important If the Genie power is accidentally cut off during the firmware update such as a electrical source power failure or human...

Страница 33: ...ic device search device discovery Select the Genie camera device by clicking on the camera user defined name By default the Genie camera is identified by its serial number The Genie status LED will tu...

Страница 34: ...ct it for control by CamExpert An imaging application uses any one of these attributes to identify a camera its IP address MAC address serial number or User Name Some important considerations are list...

Страница 35: ...k installer from within a batch file The batch file will have one command line As an example using the executable for Framework version 1 30 the command line is Genie_1 30 00 0171 Release exe r Import...

Страница 36: ...e DALSA Genie devices These files are located in the following directories Install Directory Sapera Install Win7_Embedded Win32 Install Directory Sapera Install Win7_Embedded Win64 The OS footprint fo...

Страница 37: ...pera LT or GigE Vision Compliant calls are used to retrieve this information and correctly identify the camera along with its characteristics Following is an overview of CamExpert displaying this info...

Страница 38: ...ws you to specify camera power up configuration For more information see Power up Configuration on page 37 Power up Configuration Saved User Settings The Power up configuration dialog allows you to sp...

Страница 39: ...Defines the image source as the sensor or one of the stored image patterns Trigger enable Free running or triggered Trigger source Selects the trigger input input pin or software Trigger delay Define...

Страница 40: ...ed camera configuration In CamExpert these parameters are available in the Camera Information tab under the Power up Configuration dialog box See Accessing Features with Sapera LT on page 83 XML featu...

Страница 41: ...DeviceVersion Displays the device version which includes the firmware release and build DeviceFirmwareVersion Displays the currently loaded firmware version manufacturer s code DeviceID Displays the...

Страница 42: ...ntrols Via CamExpert The Sensor Parameters tab groups the parameters related to the camera sensor configuration for acquisition Read Only Parameters Parameter Description Device Scan Type Displays the...

Страница 43: ...ange from 128 to 127 Binning Horizontal Enables or disables horizontal binning Possible values are Disabled or 2 pixels When set to 2 pixels the image buffer width parameter is automatically adjusted...

Страница 44: ...ore digitization Black level offset increases the brightness of the video signal equally Therefore any area of the video that is black will brighten to some gray level as offset is increased Black lev...

Страница 45: ...M1280 Maximum Frame Rate M1400 Maximum Frame Rate M1410 Maximum Frame Rate M1600 Maximum Frame Rate 1200 15 1 fps 1024 15 fps 21 7 fps 17 4 fps 960 24fps 17 fps 23 2 fps 18 3 fps 768 20 fps 29 fps 20...

Страница 46: ...ws the user to visually estimate frame rates for a chosen vertical crop value 0 0 100 0 200 0 300 0 400 0 500 0 600 0 700 0 800 0 900 0 FPS Vertical Lines Captured Frame Rates M640 M690 M1024 M1280 M1...

Страница 47: ...te due to the CCD readout architecture Window ROI Vertical and Horizontal Cropping can be combined to grab only a region of interest ROI Besides eliminating post acquisition image cropping done by sof...

Страница 48: ...OI Width Width of image region of interest must be an even value Height Height of image region of interest OffsetX Left coordinate of region of interest must be an even value OffsetY Top coordinate of...

Страница 49: ...els OffsetX in Pixels Specifies the offset in X from the left of the image when using an ROI The image buffer width is automatically adjusted to compensate for this offset OffsetY in Lines Specifies t...

Страница 50: ...only is activated a nominal 640x480 image is reduced to 320x480 If vertical binning only is activated the image is reduced to 640x240 With both binning modes activated the resulting image is 320x240 V...

Страница 51: ...ammable internal timer for frame rate and a programmable exposure period Frame rate is 0 1 fps to the maximum supported by the sensor Exposures range maximum is also dependent on the current frame rat...

Страница 52: ...posure time while grabbing else an Invalid Trigger Event may be generated This applies to any exposure mode or trigger source The Invalid Trigger Event is not catastrophic and only indicates the loss...

Страница 53: ...um see Genie Sensor Overview to 16 seconds 1 s steps Supports Synchronous Mode on page 56 timing for fastest possible frame rates Start of exposure is aligned on the next horizontal line while exposur...

Страница 54: ...Programmable Synchronous Mode Exposure Timing Programmable Reset Mode Exposure Timing Genie Monochrome Series GigE Vision Camera Operational Reference 53...

Страница 55: ...delay from active trigger edge to start of exposure Note that the user must account for the input opto coupler electrical specifications see External Inputs on page 113 Exposure is stopped by the oppo...

Страница 56: ...f exposure AcquisitionFrameRateRaw Controls the desired frame rate of the camera in mHz 0 001 Hz Only available when trigger is disabled AcquisitionFrameRateAbs Controls the desired frame rate of the...

Страница 57: ...ing and the programmable duration granularity is 1 s In the case of the Genie M640 a horizontal line occurs every 31 77 s Exposure duration is from the sensor minimum see Genie Sensor Overview up to 1...

Страница 58: ...l trigger received before the previous exposure read out sequence is complete is ignored An application can elect to receive messages about ignored triggers See Events on page 76 Reset Mode Timing exa...

Страница 59: ...mp increment source Internal 1 s Clock Input 1 Input 2 End of Readout Timestamp Reset Source Select event source for Timestamp Reset Off Input 1 Input 2 Important The timestamp reset function is descr...

Страница 60: ...Details on page 112 for connector pinout and electrical information The cable shell and shield should electrically connect the Genie chassis to computer chassis for maximum EMI protection For externa...

Страница 61: ...olarity drop down list boxes located in the INPUT Settings area allow you to specify the polarity of the Input 1 and Input 2 as either Active High or Active Low The Minimum duration field for each inp...

Страница 62: ...e FallingEdge AnyEdge TriggerDelayAbs Absolute delay to apply in us after reception of the trigger signal before starting exposure TriggerDelayRaw Absolute delay to apply in us after reception of the...

Страница 63: ...tput 1 or Output 2 buttons located at the top of the dialog box Use the Event mode drop down list box to select the required event mode The following output signal events are available Open default Cl...

Страница 64: ...Start of Exposure event mode is used when controlling a strobe light using the Genie output pin The exposure delay parameter is specified using the Sensor Parameters tab Exposure Control setting For...

Страница 65: ...e This event mode generates an output signal when an invalid input trigger is received An invalid trigger is any trigger received while the camera is engaged in frame acquisition exposure and readout...

Страница 66: ...signal when the camera begins a readout operation from the sensor Pulse On End of Readout Event Mode The Pulse On End of Readout event mode generates an output signal when the camera finishes a reado...

Страница 67: ...output signal when the acquisition process is terminated using software Pulse On Input 1 or Input 2 Event Modes The Pulse On Input 1 or Input 2 event modes generate an output signal when the specifie...

Страница 68: ...ert pulse output range 0 to 64k OutputLinePulseDuration Pulse duration in s range 0 to 64k OutputLineValue Static output state Open 0 Close 1 Genie Processing Features The Genie monochrome series of c...

Страница 69: ...ed SapLut Class implements LUT management BOOL SapAcqDevice SetFeatureValue const char featureName SapLut featureLut BOOL SapAcqDevice SetFeatureValue int featureIndex SapLut featureLut BOOL SapAcqDev...

Страница 70: ...n 128 Note If the offset data 0xff then that is a special flag indicating that the pixel is replaced with an adjacent pixel without any calculation The Flat Field calibration procedure using Sapera to...

Страница 71: ...els The sensor specification accounts for a small number of hot or stuck pixels pixels that do not react to light over the full dynamic range specified for that sensor Verify a Bright Acquisition Aim...

Страница 72: ...t during the calibration procedure Flat Field Correction Calibration Procedure The following procedure uses the CamExpert Flat Field tool the Sapera Flat Field demo is similar Calibration is the proce...

Страница 73: ...iris closed to minimum can provide such a black image Or cover the lens with a black lens cap Click on Acquire Black Image The flat field calibration tool will grab video frames analyze the pixel gra...

Страница 74: ...iant Applications Genie Sapera parameters for Flat Field Correction FlatFieldEnable Enable Flat Field Correction False 0 True 1 FlatFieldFormat RO mono 8 mono 9 mono 10 RGB FlatFieldWidth read buffer...

Страница 75: ...nd by programming the camera to do a horizontal flip Genie provides identical mounting holes on both its top and bottom side to ease installations Mount Genie Upside Down Horizontal Flip Image Flip Il...

Страница 76: ...t Pattern Selection on Sensor Tab The Genie test patterns are Horizontal ramp successive pixel s gray level is incremented by 1 to maximum pixel value then repeated until the end of line The gray leve...

Страница 77: ...see SapXferCallbackInfo class Acquisition events concerning the acquisition device specifically the Genie camera Use the Sapera Acquisition Module In the Sapera C library see CorAcqDeviceRegisterCall...

Страница 78: ...Trigger Trigger event software or external was invalid Input Event 0 External Input 1 has received a valid signal Input Event 1 External Input 2 has received a valid signal Output Event 0 External Ou...

Страница 79: ...ion parameters can be manually modified directly from CamExpert as described below Note that a number of parameters IP Configuration Mode IP Address Packet Size etc can also be modified by the Teledyn...

Страница 80: ...manual to enable jumbo packets on the NIC In most situations use the largest possible packet size supported by your network elements In order to support jumbo packets all intermediate network elements...

Страница 81: ...e a complete frame The time required may depend on the number of Genie cameras connected to the NIC and whether they transmit frames simultaneously If the timeout period is too short data will be tras...

Страница 82: ...to configure GevMACAddress 48 bit MAC address of the selected interface GevSupportedIPConfigurationLLA Indicates if LLA Auto IP is supported by the selected interface GevSupportedIPConfigurationDHCP I...

Страница 83: ...ssage are supported GevHeartbeatTimeout Current heartbeat timeout in milliseconds GevTimestampTickFrequency 64 bit value indicating the number of timestamp clock ticks in 1 second GevTimestampControlL...

Страница 84: ...such as a GigE Vision camera The class also contains functions for sending commands and registering events to devices SapAcqDevice GetFeatureInfo returns information on a feature associated with a sp...

Страница 85: ...id STRING 0 0 0 0 R W in Persistent IP mode Feature Type ENUM Feature Name Access W mode Type Values Interface RO Invalid ENUM GigE Vision DeviceScanType RO Invalid ENUM Area scan 0 Linescan 1 ColorTy...

Страница 86: ...e On Input 1 9 Pulse On Input 2 10 OutputSelectorOutput_2 RW Always ENUM Open 0 Close 1 Pulse On End of Exposure 3 Pulse On Valid Trigger 4 Pulse On Invalid Trigger 5 Pulse On Start of Readout 6 Pulse...

Страница 87: ...Name type INT32 Acces s Write mode Exponent Sample Value Boundaries DeviceMaxThroughput RO Invalid EXP10 0 1843200 0 min 0 max 0 inc 0 SensorWidth RO Invalid EXP10 0 640 1 to sensor width SensorHeigh...

Страница 88: ...TData RW N conn type Buffer FlatFieldGainBuffer RW N conn type Buffer FlatFieldOffsetBuffer RW N conn type Buffer UserBuffer see Accessing the Genie User Buffer RW N acq memory of type Buffer availabl...

Страница 89: ...BOOL True False Note 2 Prepares the Genie for an optimal acquisition start with minimal delay This feature should be set true only after all other features are set else the effect of AcquisitionArm is...

Страница 90: ...terface ENUM DeviceVendorName STRING DeviceModelName STRING DeviceVersion STRING FirmwareVersion STRING DeviceID STRING MACAddress STRING DeviceUserID STRING IPAddress STRING DeviceMaxThroughput INT32...

Страница 91: ...Feature Type LUTEnable BOOL LUTFormat ENUM LUTNumberEntries INT32 LUTData Sapera buffer Flat Field Control Feature Type FlatFieldEnable BOOL FlatFieldCalibrationEnable BOOL FlatFieldFormat ENUM FlatFi...

Страница 92: ...INT32 PolarityInput_2 ENUM DebounceInput_2 INT32 InputPinStatusInput_2 INT32 OutputSelectorOutput_1 ENUM PulseDelayOutput_1 INT32 PulseDurationOutput_1 INT32 PolarityOutput_1 ENUM OutputSelectorOutpu...

Страница 93: ...NT32 PacketSize INT32 HeartbeatTimeout INT32 MaximumPacketResend INT32 InterPacketTimeout INT32 ImageTimeout INT32 User Options Feature Type Power upConfig ENUM SaveCameraConfigurationSelecto r ENUM S...

Страница 94: ...on Disabled The event Feature Info Changed is sent Other feature properties might have changed too Forced Value The event Feature Value Changed is sent if the forced value is different from the previo...

Страница 95: ...xposure Time TRUE Trigger Enable Trigger Source Exposure Time Software Trigger Frame Per Trigger Exposure Alignment Reset Trigger Enable FALSE Trigger Source Frame Rate Trigger Delay to Integration Ex...

Страница 96: ...alid Trigger Pulse On Start of Readout Pulse On End of Readout Pulse On End of Acquisition Vertical Binning Vertical Binning Frame Rate 1 Line Off 2 Lines Buffer Height Buffer Top Buffer Height Buffer...

Страница 97: ...uration Mode Packet Size Heartbeat Timeout Inter Packet Delay Automatic Manual Packet Size Heartbeat Timeout Inter Packet Delay Max Packet Resend Max Packet Resend Optimize IP Configuration Mode DHCP...

Страница 98: ...tf No device found n return FALSE for int serverIndex 0 serverIndex serverCount serverIndex if SapManager GetResourceCount serverIndex SapManager ResourceAcqDevice 0 SapManager GetServerName serverInd...

Страница 99: ...Buffer Buffers new SapBuffer 1 userBufferSize 1 CORBUFFER_VAL_FORMAT_MONO8 if Buffers Create printf Error during Buffers creation n return FALSE Read a buffer to the caemra user buffer if pAcqDevice G...

Страница 100: ...fault case and no DHCP server must be present on the network Otherwise an IP address gets assigned by the DHCP server Windows will turn to LLA when no DHCP server answers requests coming from the NIC...

Страница 101: ...DALSA Network Configuration Tool can configure the Teledyne DALSA DHCP server on the NIC used for the GigE Vision network The Teledyne DALSA DHCP server is recommended where there are multiple NIC po...

Страница 102: ...to the camera In such a case the Teledyne DALSA Network Configuration tool includes a function to recover a Genie camera with an unknown persistent IP and set the Genie to the factory default setting...

Страница 103: ...102 Network Overview Tools Genie Monochrome Series GigE Vision Camera...

Страница 104: ...e help file for more descriptive information on CamExpert The central section of CamExpert provides access to the Genie parameters Five tabs group Genie parameters depending on their type as described...

Страница 105: ...or saved by the user Parameters pane Allows viewing or changing all acquisition parameters supported by the acquisition device CamExpert displays parameters only if those parameters are supported by t...

Страница 106: ...river CamExpert LUT Controls The Lookup Table dialog allows you to configure the LUT if it is available on the device Genie monochrome cameras support an 8 bit or 10 bit LUT To open this dialog use th...

Страница 107: ...ary pattern Boolean operation modifies all LUT entries using a Boolean operation Gamma correction modifies all LUT entries using Gamma correction function Linear invert modifies all LUT entries using...

Страница 108: ...how 3D views and the mechanical dimensions for Genie with C mount or CS mount and also for Genie with right angled lens mounts Additional notes follow the figures Genie 3D View with C mount and CS mou...

Страница 109: ...Genie C mount and CS mount Mechanical Specifications Note Overall length tolerance is 0 35mm 108 Technical Specifications Genie Monochrome Series GigE Vision Camera...

Страница 110: ...Genie 3D View with Right angle C mount and CS mount Genie Monochrome Series GigE Vision Camera Technical Specifications 109...

Страница 111: ...Genie Right angle C mount and CS mount Mechanical Specifications Note Overall length tolerance is 0 35mm 110 Technical Specifications Genie Monochrome Series GigE Vision Camera...

Страница 112: ...15mm Sensor Alignment Specification The following figure specifies the sensor alignment for Genie where all specifications define the absolute maximum tolerance allowed for production cameras Dimensio...

Страница 113: ...era 12 pin male Hirose connector The table below the figure lists the Genie I O signal specifications Pin Direction Genie Signal see details below Notes 1 Power GND 2 12V DC power supply see Camera Pe...

Страница 114: ...ernal current limiting see figure below Used as trigger or integration control External signal polarity selected via configuration parameter User programmable debounce time from 1 to 255 s See Input C...

Страница 115: ...ebounce IN 3 3V Genie RS 422 External Signal Example 4 7K Fairchild HMHA281R 01 f 680 IN IN Hirose 12 connector Event Signal Buffer driver example SN75179B Trigger Debounce IN 3 3V Genie 24 Volt Exter...

Страница 116: ...connector Output Driving a TTL User Circuit The opto coupler is typically a NEC PS2805 1 with the following characteristics Output Electrical Parameter Description Value Maximum voltage difference 13...

Страница 117: ...thernet cable type Camera Status LED The Genie has one multicolor LED to provide a simple visible indication of the operational status of the camera When more than one condition is active the LED colo...

Страница 118: ...ve provide a uniform field and longer life span compared to other light sources However they also require a camera with excellent sensitivity Halogen light sources generally provide very little blue r...

Страница 119: ...Where m is the magnification h is the image height pixel size and h is the object height desired object resolution size By similar triangles the magnification is alternatively given by OD f m These eq...

Страница 120: ...e sensitive applications The C mount Back Focal Distance is 17 52 mm while CS mount Back Focal Distance is 12 52 mm The lens selected must be for the Genie mount used else it may not be able to focus...

Страница 121: ...cal Distance Field of View A lens is designed to image objects at some limited distance range at some positive or negative magnification This defines the field of view F Number aperture The lens apert...

Страница 122: ...part of the optical path and should be handled like other optical components with extreme care Dust can obscure pixels producing dark patches on the sensor response Dust is most visible when the illum...

Страница 123: ...e sensor When compressed air cannot clean the sensor Teledyne DALSA recommends using lint free ESD safe cloth wipers that do not contain particles that can scratch the window The Anticon Gold 9 x 9 wi...

Страница 124: ...port this secure Ethernet cable All cables made in U S A all cables RoHS compliant CAT6 certified tested for near end far end crosstalk and return loss IGE 3M 3meters IGE 10M 10meters IGE 25M 25meters...

Страница 125: ...for technical information and pricing Physical Specifications Outside diameter 25 4mm 32 NS2A thread c mount thread Clear Aperture 19 5mm Thickness 3 0 0 1mm 0 00 10 00 20 00 30 00 40 00 50 00 60 00...

Страница 126: ...mount NIR UV filter the image will be projected about 1 3 of the filter thickness behind the sensor plane In order to compensate for this the fixed focus C mount lens needs to be unscrewed counterclo...

Страница 127: ...ging package manual Ethernet Switch Requirements When there is more than one device on the same network or a camera to PC separation greater than 100 meters an Ethernet switch is required Since the Ge...

Страница 128: ...to fiber transmission and vice versa It supports multimode MM fiber over distances of up to 220 m 720 ft and single mode SM fiber up to 65 km 40 mi with SC MT RJ or LC connector types Important The in...

Страница 129: ...EC FCC Declaration of Conformity 128 Technical Specifications Genie Monochrome Series GigE Vision Camera...

Страница 130: ...llow Note that even a Genie installation with no networking issue may still require optimization to perform to specification Device Not Available Device IP Error Device Available GigE Server Tray Icon...

Страница 131: ...with multiple NIC ports using LLA mode Device IP Error The GigE server tray icon shows a warning with IP errors Review the following topics on network IP problems to identify and correct the conditio...

Страница 132: ...amera is functional frame rate is as expected but image is black on page 135 Other problems The Save User Configuration function fails to save the current user settings See warning concerning Flat Fie...

Страница 133: ...Do you want to start the Windows Firewall Internet Connection Sharing ICS service If you try to manually start the Windows Firewall service by using Services you may receive the following error messag...

Страница 134: ...irmware required Important New Genie cameras installed in previously deployed systems are fully backward compatible with the older vision application New Genie cameras must not be programmed with olde...

Страница 135: ...has been seen with different NIC products Use a secured Ethernet cable when the Genie is in a high vibration environment See Ruggedized RJ45 Ethernet Cables on page 123 Check the Ethernet status LEDs...

Страница 136: ...Verify the exposure mode type is Synchronous not Reset mode See Synchronization Timing on page 56 Camera acquisition is good but frame rate is lower than expected While running CamExpert and grabbing...

Страница 137: ...tastrophic and only indicates the loss of a video frame Stopping acquisitions first will avoid this error Minimum Sapera Version Required Save User Configuration Failed An unusual error that occurred...

Страница 138: ...European Sales Teledyne DALSA Billerica office 700 Technology Park Drive Billerica Ma 01821 Tel 978 670 2000 Fax 978 670 2010 Teledyne DALSA GMBH Felix Wankel Str 1 82152 Krailling Germany Tel 49 89...

Страница 139: ...following three status files should be generated and included with the request for support The host computer network status file refer to the Teledyne DALSA Network Imaging Package user s manual for...

Страница 140: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Отзывы: