The information contained in this document is not subject to Export Control Regulation in Canada.
Calibir GXM640 IR Camera User's Manual
Technical Specifications
133
External Outputs: Using External TTL/LVTTL Drivers
User IO
Ground
User IO
Power
Signal 1
Camera IO
Interface
LVTTL/TTL
Buffer
R
(Pull-Down)
10
9
8
7
6
5
4
3
2
1
( User IO Power )
( Output 1 )
Set resistor (R) value to not
exceed output current of
I
R
= 24mA.
!
I
R
External Outputs: Using External LED Indicator
One external LED can be connected in the Common Cathode configuration.
User IO
Ground
User IO
Power
Camera IO
Interface
R
10
9
8
7
6
5
4
3
2
1
( User IO Power )
( Output 1 )
Set resistor (R) value to not
exceed output current of
I
F
= 24mA.
!
I
F