DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS
65
Dallmeier electronic
Number
The
Number
of
s tracks
should be a multiple of the number of cameras that record to an
S-Track
. This is necessary because S tracks are disabled (saved) in certain situations. In
this case the recording can only be continued if a new S track is available.
Length
This value sets the recording duration of the single secure tracks in seconds. All secure
tracks have the same length.
Save on full
When this option is activated every S track automatically will be secured when its memory
is expired. This option
deactivates
recording in a
ring memory
.
Wrap saved tracks
This option takes effect when there is no new S track available to continue the recording
(after securing an S track).
If this option is activated, the oldest secure track will be reused (overwritten). If this option
is deactivated, the recording of the corresponding camera in the S track will be stopped.
8.7.2
Manual
In the
manual
track mode the entire video memory will be segmented into memory units
automatically. Every camera / track is assigned a particular number of the memory units
manually (track size)..
NOTE
In the
manual
track mode the video memory configuration can
be modified anytime without the need to delete recordings.
Fig. 8-31: Storage units
Ø
Click into the
Units
field of the camera / track.
Ø
Set the number of storage units.
Ø
Proceed analogous for all relevant tracks.
Ø
Finally confirm with
OK
.
8.7.3
Automatic
In the
automatic
track mode the entire video memory will be segmented into memory units
automatically. When required, every camera / track is assigned one or more memory units
automatically (dynamic track size).
In the automatic track mode all tracks cover approximately the same period (depending on
the recording mode). The estimated minimal total recording time of all active tracks will be