DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS
13
Dallmeier electronic
4 Installation and mounting
The DLS is designed for stand-alone operation. As an option it may also be installed in a
19“ standard rack.
4.1
General Requirements
Unfavorable local conditions may shorten the life of the product or lead to malfunctions.
Do
not
operate DLS at places
l
with large scale dust and dirt
l
with steam or oil vapors (e.g. kitchen)
l
with direct sunlight
l
with unsuitable ambient temperatures
l
near sources of strong radiation (e. g. X-rays, radio transmitters or magnetic fields)
l
with corrosive surroundings (e.g. gases or salt water)
l
with insufficient ventilation (e. g. closed cabinet)
Comply with all the safety instructions and technical data.
4.2
Stand-alone installation
The DLS may be freely positioned in a place respecting the requirements mentioned above.
Attention should be paid to the fact that all connections are freely accessible.
4.2.1
Requirements
Computer room
This device is not for use in a computer room as defined in the „Standard for Protection of
Electronic Computer/Data Processing Equipment, ANSI/NFPA 75“.
Secured room
Manipulation and sabotage danger. A stand-alone installation should be made in secured
rooms with restricted access only.
Socket-outlet
The used socket-outlet has to be installed near the device. It has to be easily accessible.
4.2.2
Installation
Ø
Do not place the DLS upside down.
Ø
Ensure a stable and horizontal surface.
Ø
Ensure sufficient ventilation with 4 inch free space on the front, rear and right side.