DLS 4 / DLS 8 / 8 PLUS / DLS 16 / 16 PLUS
73
Dallmeier electronic
The camera will be removed from the display sequence of all the monitors. In addition the
camera can no longer be selected in sequencer/live mode and in playback/live mode to
display the live picture.
Ø
Right
-click a second time on the camera button to enable the camera again.
Event switching
Fig. 9-9: Define event switching
An interruption to the current sequencer can be defined by checking the
Event Switching
checkboxes.
Movement
An arbitrary camera can be defined to record using the
Motion Detection
recording mode.
If a movement is detected (start recording) the live picture from this camera will be displayed
for 5 seconds. After this the sequencer will continue automatically.
Contact
An arbitrary camera can be defined to record using the
Contact
recording mode. If the
recorder is started by a contact being triggered the live picture from this camera will be
displayed for 5 seconds. After this the sequencer will continue automatically.
9.3.2
CVBS display sequence
The display sequence and event switching is defined for CVBS monitors in exactly the same
way as for VGA monitors.
However, it is also possible to use the settings from the VGA monitor for the CVBS monitors.
Ø
Check the
Monitor X like VGA Monitor
checkbox.
Fig. 9-10:
Sequencer / CVBS
dialog
The
Cameras
,
Display Sequence
and
Event Switching
boxes will be disabled. Any settings
that you have already made will be ignored.