88
|
Dali Matrix PS System Installation and Commissioning Guide
Dali Wireless Proprietary and Confidential | DW-MAN-036 Rev 06
7
AI R HO ST P S & R EM OT E R F
CAB L I NG
The airHost PS and remote have a number of RF interface options for connecting to
public safety signal sources. Depending on the system design and public safety
frequency bands being used, an external pass-band filter may be required.
If an external filter is required, the unit is equipped with a number of simplex RF
interfaces. If there is no filter, the RF feed connects directly to an internal duplexer or
multiplexer.
The number of RF interfaces available on the unit depends on the
RF design. This chapter describes airHost PS and remote units
with the maximum number of interfaces for each type 1 and
type 2 chassis
This chapter describes how to:
Connect RF feeds to units with simplex interfaces and connected to an external
filter
Connect RF feeds to units with an internal duplexer or multiplexer
7.1
RF Cabling Requirements
If a pass-band filter is used, ensure the equipment is installed according to
manufacturer instructions.
Terminate coaxial cables with N-type male connectors.
Apply 12-15 in-lbs (136 N-cm) torque to secure the cables.