Dali Matrix PS System Installation and Commissioning Guide
Dali Wireless Proprietary and Confidential | DW-MAN-036 Rev 06
Next, open the Alarm Summary or alarms per band to see alarm details.
For information about displaying and clearing alarms, see
18.2
Monitoring Alarms for Broken Optical Links
There are several types of broken optical link alarms for both host units and remotes.
In the following table,
upstream
refers to units or optical links closest to the base station
or off-air signal source, and
downstream
refers to units or optical links farthest away.
For example, in Figure 18-2 Host A is the upstream unit, and Host B is the downstream
unit. Remote A is the upstream unit relative to Remote B, but also the downstream
remote relative to Host A.
Alarm Name
Description
Severity Alarm LED
Sync Loss on Downstream
Optical Link
Displays on an upstream unit when there
is a downstream optical link failure
causing the downstream unit to be offline
or disconnected.
For downstream host units, this means all
connected remotes are offline. Critical
action may be required.
Optical Link Failure Alarms on Daisy-
Minor
Orange
Sync Loss on Upstream
Optical Link
Displays on a downstream unit when
there is an upstream optical link failure
causing this unit to be offline or
disconnected.
Critical
Red/Orange
alternating