154
|
Dali Matrix PS System Installation and Commissioning Guide
Dali Wireless Proprietary and Confidential | DW-MAN-036 Rev 06
RF Module Status
Description
Standby
RF module has powered on successfully.
RF module is not sending or receiving RF signals.
RF module is ready for configuration or servicing (such as upgrades or
restarts).
Clicking Standby activates the module, changing the status to Active.
Active
RF module is sending or receiving RF signals.
Minor or major alarms may be present.
Clicking Active deactivates the module, changing the status to
Standby.
Failed
A module critical alarm has occurred and the RF path has been
deactivated.
Always accompanied by a critical alarm which indicates the cause of
the failure
RF module may recover and return to Active automatically. If the RF
module cannot recover, then the module can be placed in Standby
manually.
Clicking Failed deactivates the module, changing the status to
Standby.
Activating
RF module is changing from Standby to Active (displays briefly
Missing
RF module has been physically removed.
Always accompanied by an associated critical alarm.
May change to Standby if the module is replaced.
If the module is replaced elsewhere or the slot is reused, the critical
alarm is cleared.
RF module cannot be configured while Missing.
No Link
All optical links on a remote are also showing No Link. For more
information, see
RF modules are deactivated to prevent damaging optical signals from
being passed over the optical link.
When all optical links have been restored, the modules return to
Active or Failed status.