Matrix PS System Installation and Commissioning Guide
|
43
Dali Wireless Proprietary and Confidential | DW-MAN-036 Rev 06
Item
Description
Disconnect device
The host is considered as permanently connected device. A readily
accessible disconnect device shall be incorporated external to the
equipment.
2.4.4
Cables
The cable requirements for Matrix PS units will vary according to the nature and size of
the system deployment, as well as the required adherence to local, state, and federal
regulations.
The following cables need to be fabricated on site.
Item
Description
Host DC power cable
Required only if not using a Matrix AC/DC power supply. Use 2-wire or 3-
wire multi-conductor AWG #12, #14, or #16 stranded bare copper with
unshielded outer jacket to connect the fuse panel and the host.
Remote DC power cable
Required only if not using Matrix AC/DC power supply. Use 2-wire or 3-wire
multi-conductor AWG #12, #14, or #16 stranded bare copper with
unshielded outer.
RF cable
1/2-inch, or 7/8-inch coaxial cable
Always consider the minimum bend radius provided by the cable
manufacturer for the cable used.
Ethernet cable
CAT 5 Ethernet cables with RJ-45 connectors
Optical fiber
Single-mode optical fiber (SMF 9/125 µm)