Si39-406
Operation Procedure
Operation Manual
203
Explanation of heating operation
Defrost operation
In heating operation, freezing of the outdoor unit coil increases. Heating capability decreases
and the system goes into defrost operation.
The indoor unit fan stops and the remote controller displays
“
”.
After maximum 10 minutes of defrost operation, the system returns to heating operation again.
Hot start
In order to prevent cold air from blowing out of an indoor unit at the start of heating operation,
the indoor fan is automatically stopped. The display of the remote controller shows “
”.
5.2
Program Dry Operation
The function of this program is to decrease the humidity in your room with a minimum
temperature decrease.
The micro computer automatically determines temperature and fan speed.
The system does not go into operation if the room temperature is low.
For systems without cool/heat changeover remote control switch
Press the operation mode selector button several times and select “
” (program dry
operation).
Press the on/off button
The operation lamp lights up and the system starts operation.
Press the air flow direction adjust button. Refer to the chapter “Adjusting the air flow
direction” for details.
Stopping the system
Press the on/off button once again.
The operation lamp goes off and the system stops operation.
Note:
Do not turn off power immediately after the unit stops, but wait for at least 5 minutes.
1
2
3
4
Содержание REYQ96MTJU
Страница 1: ...Design Installation Testing Instruction R410A Heat Recovery 60Hz REYQ96MTJU Si39 406...
Страница 6: ...Si39 406 iv Table of Contents...
Страница 34: ...Installation Si39 406 28 General Information Flaring Procedure...
Страница 68: ...Installation Si39 406 62 General Information Caution Caution label 3P124617 4P124614...
Страница 114: ...Appendix Si39 406 108 General Information 3P135887 1...
Страница 124: ...Appendix Si39 406 118 General Information 7 8 Piping System Diagrams 7 8 1 Outdoor Unit REYQ96MTJU 4D045329...
Страница 126: ...Appendix Si39 406 120 General Information 7 8 3 BS Unit BSVQ36MVJ BSVQ60MVJ 4D045338...
Страница 127: ...Si39 406 Appendix General Information 121 7 9 Wiring Diagrams 7 9 1 Outdoor Unit REYQ96MTJU 3D044892A...
Страница 128: ...Appendix Si39 406 122 General Information 7 9 2 Field Wiring REYQ96MTJU 3D042647A...
Страница 156: ...Refrigerant Piping Si39 406 150 Installation Manual REYQ96MTJU...
Страница 158: ...Refrigerant Piping Si39 406 152 Installation Manual REYQ96MTJU...
Страница 230: ...Precautions for New Refrigerant R410A Si39 406 224 Precautions for New Refrigerant R410...
Страница 236: ...375 Park Avenue Suite 3308 New York N Y 10152 info daikinac com www daikinac com...