10/10
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Installer setting at variance with
default value
Field settings table
9.I
[D-0A]
0
9.I
[D-0B]
2
9.I
[E-00]
R/O
0~5
0: LT split
9.I
[E-01]
R/O
0
9.I
[E-02]
R/W (*6)
R/O (*7)
0: Reversible (*6)
1: Heating only (*7)
9.I
[E-03]
R/O
2: 3V (*1)
3: 6V (*2)
4: 9W (*3)
9.I
[E-04]
R/O
0: No
1: Yes
9.I
[E-05]
R/W
0: No (*4)
1: Yes (*5)
9.I
[E-06]
R/O
0: No
1: Yes
9.I
[E-07]
R/W
0~6
0: EKHW (*4)
1: Integrated (*5)
5: EKHWP (*4)
9.I
[E-08]
R/O
1: Enabled
9.I
[E-09]
1
9.I
[E-0A]
0
9.I
[E-0B]
0
9.I
[E-0C]
0
9.I
[E-0D]
0
9.I
[E-0E]
0
9.I
[F-00]
R/W
0: Disabled
1: Enabled
9.I
[F-01]
R/W
10~35°C, step: 1°C
20°C
9.I
[F-02]
R/W
3~10°C, step: 1°C
3°C
9.I
[F-03]
R/W
2~5°C, step: 1°C
5°C
9.I
[F-04]
R/W
0: No
1: Yes
9.I
[F-05]
0
9.I
[F-09]
R/W
0: Disabled
1: Enabled
9.I
[F-0A]
0
9.I
[F-0B]
R/W
0: No
1: Yes
9.I
[F-0C]
R/W
0: No
1: Yes
9.I
[F-0D]
R/W
0: Continuous
1: Sample
2: Request
--
Which type of unit is installed?
Which type of compressor is installed?
--
What is the indoor unit software type?
What is the number of backup heater steps?
Is the power saving function available on the outdoor unit?
Pump operation allowed outside range.
Is glycol present in the system?
--
Above which outdoor temperature is cooling allowed?
Bottom plate heater ON temperature.
Bottom plate heater hysteresis.
Can the system prepare domestic hot water?
Is a DHW tank installed in the system?
What kind of DHW tank is installed?
Power saving function for outdoor unit.
--
--
Close shut-off valve during cooling?
What is the pump operation mode?
Is a bottom plate heater connected?
--
Pump operation during flow abnormality.
--
Close shut-off valve during thermo OFF?
Is a bi-zone kit installed?
--
4P495257-1A - 2017.11
(#) Setting is not applicable for this unit.
(*1) *3V_(*2) *6V_
(*3) *9W_(*4) *HB*_
(*5) EHV*_
(*6) *X*_(*7) *H*
Final English - Tanslations in progress