7 Installation
Installer reference guide
30
ERGA04~08DAV3(A) + EHVH/X04+08S18+23DA
Daikin Altherma – Low temperature split
4P495248-1 – 2017.12
2
1
1
3
3
If necessary, remove the front plate. This is, for example,
necessary in the following cases:
▪
"7.2.5 To lower the switch box on the indoor unit" on
page 30
▪
"7.8.5 To connect the drain hose to the drain" on page 40
▪ When you need access to the high voltage switch box
2×
T25
7.2.4
To open the switch box cover of the
indoor unit
4×
T25
4×
T25
7.2.5
To lower the switch box on the indoor unit
During the installation, you will need access to the inside of the
indoor unit. To have easier front access, put the switch box lower on
the unit as follows:
Prerequisite:
The user interface panel and front panel have been
removed.
1
Remove the top panel that keeps the switch box into place at
the top of the unit.
2
Tilt the switch box to the front and lift it out of its hinges.
1
2
2×
T25
3
Place the switch box lower on the unit. Use the 2 hinges located
lower on the unit.
3
3
Final English - Tanslations in progress