Instruction
Si18-525B
282
Operation Manual
door drain pipes during air-conditioning opera-
tion, chances are that dust and dirt are clogged
in the pipe. This may result in a water leakage
from the indoor unit. Under such circumstances,
stop the operation of the air conditioner, and then
con sult your dealer or our service station.
• Operating procedure varies with heat pump type
and cooling only type. Contact your Daikin dealer
to confirm your system type.
• To protect the unit, turn on the main power switch
6 hours before operation.
5. NAME AND FUNCTION OF
EACH SWITCH AND DISPLAY
ON THE REMOTE
CONTROLLER
1
ON/OFF BUTTON
Press the button and the system will start.
Press the button again and the system will
stop.
2
OPERATION LAMP (RED)
The lamp lights up during operation.
3
DISPLAY “
” (UNDER CENTRAL-
IZED CONTROL)
When this display shows, the system is
UNDER CENTRALIZED CONTROL.
4
DISPLAY “
” “
” “
” “
”
(VENTILATION/AIR CLEANING)
This display shows that the total heat
exchange and the air cleaning unit are in
operation (These are optional accessories).
5
DISPLAY “
” “
” “
” “
” “
”
(OPERATION MODE)
This display shows the current OPERATION
MODE. For cooling only type, “
” (Auto)
and “
” (Heating) are not installed.
6
DISPLAY “ TEST
” (INSPECTION/TEST
OPERATION)
When the INSPECTION/TEST OPERATION
BUTTON is pressed, the display shows the
system mode is in.
7
DISPLAY “
” (PROGRAMMED TIME)
This display shows the PROGRAMMED
TIME of the system start or stop.
8
DISPLAY “
” (SET TEMPERATURE)
This display shows the set temperature.
9
DISPLAY “
” (FAN SPEED)
This display shows the set fan speed.
10
DISPLAY “
” (AIR FLOW FLAP)
Refer to “AIR FLOW DIRECTION ADJUST”.
Refer to figure 1 on page
[1]
11
DISPLAY “
” (TIME TO CLEAN AIR
FIL-TER)
Refer to “HOW TO CLEAN THE AIR FILTER”.
12
DISPLAY “
”
(DEFROST)
Refer to “DEFROST OPERATION".
13
NON-FUNCTIONING DISPLAY
If that particular function is not available,
pressing the button may display the words
“NOT AVAILABLE” for a few seconds.
When running multiple units simultaneously
The “NOT AVAILABLE” message will only be
appear if none of the indoor units is equipped
with the function. If even one unit is equipped
with the function, the display will not appear.
14
TIMER MODE START/STOP BUTTON
Refer to “PROGRAM TIMER OPERATION”.
15
TIMER ON/ OFF BUTTON
Refer to “PROGRAM TIMER OPERATION”
16
INSPECTION/TEST OPERATION BUT-
TON
This button is used only by qualified service
persons for maintenance purposes.
17
PROGRAMMING TIME BUTTON
Use this button for programming “START and/
or STOP” time.
18
TEMPERATURE SETTING BUTTON
Use this button for SETTING TEMPERA-
TURE.
19
FILTER SIGN RESET BUTTON
Refer to “HOW TO CLEAN THE AIR FILTER”.
20
FAN SPEED CONTROL BUTTON
Press this button to select the fan speed,
HIGH or LOW, of your choice.
21
OPERATION MODE SELECTOR BUTTON
Press this button to select OPERATION MODE.
22
AIR FLOW DIRECTION ADJUST BUTTON
Refer to “AIR FLOW DIRECTION ADJUST”.
NOTE
• For the sake of explanation, all indications are
shown on the display in figure 1 contrary to
actual running situations.
6. OPERATION PROCEDURE
Refer to figure 1 on page
[1]
Содержание D-Series
Страница 1: ...Si18 525B Applied Models Super Multi Plus Cooling only Super Multi Plus Heat Pump D Series ...
Страница 33: ...List of Functions Si18 525B 20 List of Functions ...
Страница 34: ...Si18 525B Specifications 21 Part 2 Specifications 1 Specifications 22 1 1 Cooling Only 22 1 2 Heat Pump 42 ...
Страница 71: ...Specifications Si18 525B 58 Specifications ...
Страница 107: ...Printed Circuit Board Connector Wiring Diagram Si18 525B 94 Printed Circuit Board Connector Wiring Diagram ...
Страница 117: ...Refrigerant Flow for Each Operation Mode Si18 525B 104 Refrigerant Circuit ...
Страница 171: ...Indoor Unit SkyAir Models Si18 525B 158 Function ...
Страница 207: ...Test Operation and Field Setting for RA Indoor Unit Si18 525B 194 Test Operation ...
Страница 336: ...Si18 525B Service Check Function Troubleshooting 323 ...
Страница 443: ...BP Unit Si18 525B 430 Removal Procedure The clamps are to be kept in stock Step Procedure Points Clamps Q0529 ...
Страница 469: ...Wiring Diagrams Si18 525B 456 Appendix ...
Страница 475: ...Si18 525B vi Index ...