15
|
Technical data
Installer reference guide
225
EHYH EHYHBH/X08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1F – 2020.10
SHEET METAL
Terminal strip on fixed plate
SW1, SW3
Push buttons
SW2, SW5
DIP switches
U
Connector
V
Connector
V2, V3, V401
Varistor
W
Connector
X11A, X12A
Connector
X1M, X2M
Terminal strip
Y1E
Electronic expansion valve coil
Y1R
Reversing solenoid valve coil
Z1C~Z4C
Ferrite core
Field wiring
Terminal strip
Connector
Terminal
Protective earth
BLK
Black
BLU
Blue
BRN
Brown
GRN
Green
ORG
Orange
PPL
Purple
RED
Red
WHT
White
YLW
Yellow
15.4 Wiring diagram: Indoor unit
See the internal wiring diagram supplied with the unit (on the inside of the indoor unit switch box cover). The
abbreviations used are listed below.
Notes to go through before starting the unit
English
Translation
Notes to go through before starting the
unit
Notes to go through before starting the
unit
X1M
Indoor/outdoor communication
X2M
Field wiring terminal for AC
X5M
Field wiring terminal for DC