8
|
Configuration
Installer reference guide
158
EHYH EHYHBH/X08AF + EHYKOMB33AA
Daikin Altherma hybrid heat pump
4P355634-1F – 2020.10
NOTICE
Disinfection mode
. Even if you turn OFF domestic hot water operation via the
DHW tank temperature home page (
Tank
), disinfection mode will remain active.
INFORMATION
Disinfection function is restarted in case the domestic hot water temperature drops
5°C below the disinfection target temperature within the duration time.
INFORMATION
An AH error occurs if you do the following during disinfection:
▪
Set the user permission level to Installer.
▪
Go to the DHW tank temperature home page (
Tank
).
▪
Press to interrupt the disinfection.
Heat source settings
Auto emergency
When the heat pump fails to operate, the gas boiler can serve as an emergency
back-up heater and either automatically or non-automatically take over the entire
heat load.
▪
When auto emergency is set to
Automatic
and a heat pump failure occurs, the
boiler will automatically take over the heat load.
▪
When auto emergency is set to
Manual
and a heat pump failure occurs, the
domestic hot water and space heating operations will stop and need to be
recovered manually. The user interface will then ask the user to confirm whether
the boiler can take over the entire heat load or not.
When the heat pump fails, will appear on the user interface. If the house is
unattended for longer periods, we recommend to set [A.6.C]
Emergency
to
Automatic
.
#
Code
Description
[A.6.C]
N/A
Emergency
:
▪
0:
Manual
(default)
▪
1:
Automatic
INFORMATION
The auto emergency setting can be set in the menu structure of the user interface
only.
INFORMATION
If a heat pump failure occurs and [A.6.C] is set to
Manual
, the room frost protection
function, the underfloor heating screed dryout function, and the water pipe
antifreeze function will remain active even if the user does NOT confirm emergency
operation.
Equilibrium temperature
Based on the ambient temperature, energy prices and the required leaving water
temperature, the user interface is able to calculate which heat source can deliver
the required heating capacity most efficiently. However, to maximise the energy
output of the heat pump, it is possible to prevent the gas boiler from operating
Содержание Altherma EVLQ05+08CA