![Daikin Altherma EHFH03S18D 3V Series Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/daikin/altherma-ehfh03s18d-3v-series/altherma-ehfh03s18d-3v-series_installers-reference-manual_4358338051.webp)
6
|
Application guidelines
Installer reference guide
51
E EHFH03S18D
Daikin Altherma 3 R F
4P596806-1C – 2022.09
Power meter types
Single-phase power meter.
6.6 Setting up the power consumption control
You can use the following power consumption controls. For more information
about the corresponding settings, see
136].
#
Power consumption control
1
"6.6.1 Permanent power limitation"
▪
Allows you to limit the power consumption of the entire heat pump
system (sum of indoor unit and backup heater) with one permanent
setting.
▪
Limitation of power in kW or current in A.
2
"6.6.2 Power limitation activated by digital inputs"
▪
Allows you to limit the power consumption of the entire heat pump
system (sum of indoor unit and backup heater) via 4 digital inputs.
▪
Limitation of power in kW or current in A.
NOTICE
Set a minimum power consumption of ±3.6 kW to guarantee:
▪
Defrost operation. Otherwise, if defrosting is interrupted several times, the heat
exchanger will freeze up.
▪
Space heating and DHW production by allowing the backup heater step 1.
▪
Disinfection operation.
6.6.1 Permanent power limitation
Permanent power limitation is useful to assure a maximum power or current input
of the system. In some countries, legislation limits the maximum power
consumption for space heating and DHW production.
P
i
t
DI
a
b
P
i
Power input
t
Time
DI
Digital input (power limitation level)
a
Power limitation active
b
Actual power input
Setup and configuration
▪
No additional equipment needed.