10
|
Configuration
Installer reference guide
139
E EHFH03S18D
Daikin Altherma 3 R F
4P596806-1C – 2022.09
Leaving water temperature maximum modulation
ONLY applicable in room thermostat control and when modulation is enabled. The
maximum modulation (=variance) on the desired leaving water temperature
decided on the difference between the actual and desired room temperature, e.g.
3°C modulation means the desired leaving water temperature can be increased or
lowered by 3°C. Increasing the modulation results in better performance (less On/
OFF, faster heat up), but note that depending on the heat emitter, there MUST
ALWAYS be a balance (see the design and selection of the heat emitters) between
the desired leaving water temperature and the desired room temperature.
#
Code
Description
N/A
[8-06]
0°C~10°C
Weather-dependent cooling allowance
It is possible to disable weather-dependent cooling, meaning the desired leaving
water temperature in cooling operation does NOT depend on the outdoor ambient
temperature and this regardless whether weather-dependent is selected or NOT.
Both for the main leaving water temperature zone as for the additional leaving
water temperature zone, this can be set separately.
#
Code
Description
N/A
[1-04]
Weather-dependent cooling of the main leaving
water temperature zone is…
▪
0 (disabled)
▪
1 (enabled)
N/A
[1-05]
Weather-dependent cooling of the additional
leaving water temperature zone is…
▪
0 (disabled)
▪
1 (enabled)
Temperature ranges (room temperature)
ONLY applicable in room thermostat control. In order to save energy by preventing
overheating or undercooling the room, you can limit the range of the room
temperature.
NOTICE
When adjusting the room temperature ranges, all desired room temperatures are
also adjusted to guarantee they are between the limits.
#
Code
Description
Room temp. range
[A.3.2.1.2]
[3-06]
Maximum temp (heating)
18°C~30°C
[A.3.2.1.1]
[3-07]
Minimum temp (heating)
12°C~30°C
[A.3.2.1.4]
[3-08]
Maximum temp (cooling)
25°C~35°C
[A.3.2.1.3]
[3-09]
Minimum temp (cooling)
15°C~25°C