6
|
Application guidelines
Installer reference guide
32
E EHFH03S18D
Daikin Altherma 3 R F
4P596806-1C – 2022.09
Underfloor heating or radiators – Wireless room thermostat
Setup
A
B
b
a
A
Main leaving water temperature zone
B
One single room
a
Receiver for wireless external room thermostat
b
Wireless external room thermostat
▪
For more information about connecting the electrical wiring to the unit, see:
-
"9.2 Connections to the outdoor unit"
-
"9.3 Connections to the indoor unit"
▪
The underfloor heating or radiators are directly connected to the indoor unit.
▪
The room temperature is controlled by the wireless external room thermostat
(optional equipment EKRTR1 or EKRTRB).
Configuration
Setting
Value
Unit temperature control:
▪
#: [A.2.1.7]
▪
Code: [C-07]
1 (
Ext RT control
): Unit operation
is decided by the external thermostat.
External room thermostat for the
main
zone:
▪
#: [A.2.2.4]
▪
Code: [C-05]
1 (
Thermo ON/OFF
): When the used
external room thermostat or heat pump
convector can only send a thermo ON/
OFF condition.
Benefits
▪
Wireless.
The Daikin external room thermostat is available in a wireless version.
▪
Efficiency.
Although the external room thermostat only sends ON/OFF signals, it
is specifically designed for the heat pump system.
▪
Comfort.
In case of underfloor heating, the wireless external room thermostat
prevents condensation on the floor during cooling operation by measuring the
room humidity.