
7
|
Unit installation
Installer reference guide
83
ERLA11~W1 + EBVH16SU23DJ
Daikin Altherma 3 R F
4P655196-1 – 2021.09
(mm)
758
>150
(480-490)
485
4× M12
a
a
Make sure not to cover the drain holes. See
INFORMATION
The recommended height of the upper protruding part of the bolts is 20 mm.
20
NOTICE
Fix the outdoor unit to the foundation bolts using nuts with resin washers (a). If the
coating on the fastening area is stripped off, the metal can rust easily.
a
7.3.4 To install the outdoor unit
1
To handle the unit and to put in onto the installation structure, see
handle, unpack and remove accessories – Outdoor unit"
22].
2
Fix the unit to the installation structure.
4× M12
Содержание Altherma 3 R F
Страница 309: ...13 13 ...
Страница 310: ......
Страница 311: ......
Страница 312: ...4P655196 1 2021 09 Copyright 2021 Daikin Verantwortung für Energie und Umwelt ...