7
|
Unit installation
Installer reference guide
78
ERLA11~W1 + EBVH16SU23DJ
Daikin Altherma 3 R F
4P655196-1 – 2021.09
Total refrigerant charge (kg)
A
nv-min
(dm²)
4.2
10.4
4.4
10.6
4.6
10.9
4.8
11.1
5
11.3
5.2
11.5
5.4
11.8
5.6
12.0
5.8
12.2
7.2 Opening and closing the units
7.2.1 About opening the units
At certain times, you have to open the unit.
Example:
▪
When connecting the refrigerant piping
▪
When connecting the electrical wiring
▪
When maintaining or servicing the unit
DANGER: RISK OF ELECTROCUTION
Do NOT leave the unit unattended when the service cover is removed.
7.2.2 To open the outdoor unit
DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF BURNING/SCALDING
(4)
2
1
1×
PH2
8
mm
3