![Daher TBM 900 Скачать руководство пользователя страница 963](http://html.mh-extra.com/html/daher/tbm-900/tbm-900_pilots-information-manual_499727963.webp)
Pilot's Operating Handbook
Supplement 77
Installation of the PT6A-66D Build Spec 1354
engine on the TBM 900 airplane
Edition 0 - April 15, 2021
Rev. 0
Page 9.77.5
The following conditions are given for all the tables (pages 9.77.6 to 9.77.13) :
●
NOTE
●
Inertial separator must be OFF and BLEED HI msg OFF.
●
-
Landing gear and flaps UP.
-
BLEED switch on AUTO.
-
represent the ISA conditions at the flight level.
The torque must be set at or below the value corresponding to the local conditions of
flight level and temperature.
●
NOTE
●
The engine ITT limit at 840
°
C during continuous operation may be used in case
of operational need.
●
Example, for conditions :
-
FL = 260
-
OAT = - 22
°
C
the following tables give the maximum torque to be set.
Maximum climb power
TRQ setting = 83 % for IAS = 124 KIAS (Add 0.5 % of TRQ for each additional 10 KIAS
on climb airspeed), cf. tables figures 9.77.2 and 9.77.2A
Maximum cruise power
TRQ setting = 97 %, cf. tables figures 9.77.4 and 9.77.4A
Recommended cruise power
TRQ setting = 92 %, cf. tables figures 9.77.5 and 9.77.5A
PIM - DO NOT USE FOR FLIGHT OPERATIONS