![Daher TBM 900 Скачать руководство пользователя страница 168](http://html.mh-extra.com/html/daher/tbm-900/tbm-900_pilots-information-manual_499727168.webp)
Pilot's Operating Handbook
Section 3
Emergency procedures
EASA Approved
Edition 0 - October 31, 2013
Rev. 6
Page 3.10.6
>> With v15.11 GARMIN software (Post-MOD70-0407-00D) and without EDM
evolution patch (Pre-MOD70-0657-34)
and
and
CABIN ALTITUDE
USE OXYGEN MASK
EDM
●
NOTE
●
CABIN ALTITUDE
is followed by
USE OXYGEN MASK
and 3 voice alerts
“Use oxygen mask / Use oxygen mask”.
EDM makes a 90° left heading change and descent to 15000 ft.
EDM override is possible by pressing twice the AP / TRIM DISC push-button,
and other AP modes are usable.
Power reduction to speed up the descent is recommended.
●
Indicates a cabin altitude over 10000 ft ± 500 ft.
1 -
Pressurization indicator
Check
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If cabin altitude > 10000 ft ± 500 ft :
2 -
Oxygen masks
Use
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
►
Fly the airplane
◄
3 -
BLEED switch
Check AUTO
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 -
DUMP switch
Check NORM / Guarded
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 -
EMERGENCY RAM AIR control knob
Check pushed
. . . . . . . . . . . . . . . . . . .
If necessary :
6 -
Perform procedure
Emergency descent
. . . . . . . . . . . . . . . . . . . . . . . . .
Refer to chapter 3.6
7 -
Limit flight altitude to maintain cabin altitude below 10000 ft.
Inform maintenance department before next flight.
End of procedure.
PIM - DO NOT USE FOR FLIGHT OPERATIONS